×
Siemens Industry Online Support
Siemens AG
Entry type: Application example Entry ID: 106226404, Entry date: 04/09/2019
(100)
Rate

Toolbox for HMI Projects

  • Entry
  • Associated product(s)
It is often the small tools that make work easier. This entry contains some useful tools that you can easily integrate into your HMI configuration via libraries. For example, a stopwatch, a file explorer or also a calculator, .... The toolbox for HMI projects currently offers 29 tools already and is continuously expanded.

The HMI toolbox of Siemens Industry Online Support provides many useful tools that can clearly make every day work easier.
The different tools are available in global libraries and can thus be easily integrated in your visualization. This saves you valuable development time that you would have to invest in the development of separate tools.

The HMI toolbox comprises tools for six different subject areas.



Picture 01


All tools in one example
In the example project you can test the functions of all tools. In order to use them in your own project, use the respective libraries and documentation.

Time functions                           

Time functions are an elementary part of production. Instead of external “tools” such as, for example, a wall calendar, you can integrate the calendar directly into your visualization and make work much easier for the operator.

Tools

Basic
HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels

WinCC

RT Advanced

WinCC

RT
Professional

S7-
1200
S7-
1500

Alarm

 xorxorxandxorx

Calendar

xorxorx

Stopwatch

xorxorxandx

Timer

xorxorxandx

Time switch

 xorx
    

World clock

xorx



Data transfer                         

Exchanging data between devices or persons is one of the basic requirements of automation technology. How can the operators of a large, distributed plant communicate with each other quickly and efficiently? How can you transfer the article number of a defective device to your cell phone so that you can retrieve the information when back at your desk?
Please use the following tools.

Tools

Basic
HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels
WinCC
RT Advanced
WinCC
RT
Professional
S7-
1200
S7-
1500

Chat

xorx

Barcode

xorxorxorx

QR Code

xorxorx

Email

xorxorx

Automatic data backup
of files

xorxorx



Mathematical functions                         

Small calculations are a fixed part of the daily work routine of an operator. If products are manufactured for different regions, converting the units can be a lot of work. Small tools can help the operator and prevent minor errors.

Tools

Basic
HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels
WinCC
RT
Advanced
WinCC
RT
Professional
S7-
1200
S7-
1500

Unit converter

xorxorx

Calculator

xorxorx



Simplified operation                         

The user interface of the panels in the plant should be intuitive and with an easy to use design. It can support operators with functions they know from everyday life such as a home button that executes different functions depending on whether it is pressed for short or long time.

Tools

Basic HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels

WinCC
RT Advanced

WinCC
RT
Professional
S7-1200 S7-
1500

On-Screen Keyboard

xorx

Home button

xorxandx

Individual screen saver (solution 1)

xorx

Individual screen saver (solution 2)

xorxorxandxorx

Check/radiobox

xorx
Move Pop-up screens  xor x      

Segmented control

xorxorx



Increase clarity                          

To enable your operators to work in a structured way, the clarity of the user interface has to be paramount. TIA Portal provides several options, for example, to align elements with each other. The tools included here, such as, a notes function, round off these options.


Tools

Basic HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels

WinCC
RT
Advanced

WinCC
RT
Professional
S7-
1200
S7-
1500

Notes

xorxorx

Gauge Controls for Basic Panels

x

Gauge Controls for Comfort Panels / WinCC RT Advanced

  x or x      

File explorer

xorxorx

Table View for Logs

xorx

Changing background by call of Pop-Up screens

xorx

Waiting view

xorxorx

Percentage view

   xor x      

Bit monitor1

   xor x x     
CMD1      x    

1 new tool for WinCC RT Professional


Simplified Engineering                          

Not only plant operators but also their engineers can be supported by little tools. With the aid of the rotation tool (MS Office AddIn), you can create a rotating object from any graphic and use it as a graphic list in your WinCC (TIA Portal) project.

As of TIA Portal V14 (WinCC Basic/Comfort/Advanced/Professional) you can use the "Siemens TIA Portal Icons Standard" font. The font provides frequently used graphic icons as typeset. This saves you development time for individual icons.
You can find an overview about the symbols and a describition about the implementation of the font in the documentation.
 

Tools

Basic HMI

Advanced HMI
Panel-based

Advanced HMI
PC-based
S7 controller
Basic PanelsComfort Panels
Mobile Panels

WinCC
RT
Advanced

WinCC
RT
Professional
S7-
1200
S7-
1500

Siemens icon font

xorxorxorx



SITRAIN trainings near you for WinCC (TIA Portal) machine level (Panels and WinCC RT Advanced)
WinCC (TIA Portal) basic / system training: 109758624
WinCC (TIA Portal) advanced training: 109758626 

SITRAIN trainings near you for WinCC (TIA Portal) SCADA (WinCC RT Professional)
WinCC (TIA Portal) basic / system training: 109758618

Additional Informationen
SIMATIC HMI Option +: 109754400
HMI Template Suite(Product page)
HMI Template Suite for HMI devices (Download page): 91174767

Last Changes
Update of example projects and libraries for Panels / WinCC RT Advanced / WinCC RT Professional V15.1.
New tools "Bit monitor" and "CMD" available for WinCC RT Professional

Additional Keywords
physical, units of measure, mcs, conversion, calculator, calendar, faceplate, example, configuration example, application example, applications, functional example, functions, example blocks, demo project, mini libraries, apps, fonts, bit view, percentage, percentageview, percent, cmd,



Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
http://www.siemens.com/industrialsecurity.
Support to the statistics
With this function the IDs found are listed according to number (format .txt).

Generate list
Copy URL
Display page in new design
mySupport Cockpit