With active referencing, why does the parameter for the approach direction not match the actual approach direction?

  • Entry
  • Associated product(s)

The technological objects PositioningAxis (S7-1200 CPU, S7-1500 CPU) and SynchronousAxis (S7-1500 CPU) have the parameter "Homing.ApproachDirection" for setting the approach direction to a reference point switch.

Contrary to the current documentation (SIMATIC S7-1500 S7-1500 Motion Control V13 Update 3, TIA Portal V13 SP1 Update 7 Online Help), the parameter is set as follows:

FALSE: Positive approach direction
TRUE: Negative approach direction

Additional Keywords
TO, Motion Control, Axis, Referencing, To reference, Reference switch, Reference, Technology Object

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit