×
Siemens Industry Online Support
Siemens AG
Entry type: Product note Entry ID: 109486162, Entry date: 02/25/2019
(26)
Rate

Status change for SIMATIC HMI products

  • Entry
  • Associated product(s)
This product notification provides information about upcoming status changes to SIMATIC HMI products because our SIMATIC products are subject to PLM (Product Lifecycle Management).

The PLM and its milestones are explained in detail here 91688124.

The following table contains the current status of new products and the corresponding dates.




Classic family

This should be taken into consideration in time for project planning and spare parts management. The current status of a product for an article number can also always be seen in the mall or product presentation in Siemens Online Support (SIOS).

This list provides only an overview and shows the milestone planning. The milestone shown with the article number in Online Support is always valid!

Updated: 02/2019


Article numberType  SuccessorStatus validas of 

 Spare part

Note

 6AV3688-3AA03-0AX0 PP7 KP8(F) P.M410 1 July 2017W
 6AV3688-3CD13-0AX0 PP17 I 2x KP8 or KP32(F) P.M410 1 July 2017W
 6AV3688-3ED13-0AX0 PP17 II KP32(F) P.M410 1 July 2017W
 6AV3017-1NE30-0AX0 TD17 6AV3017-1NE30-0AX1 P.M500 1 Oct. 2018-
 6AV3017-1NE30-0AX1 TD17 Basic Panel P.M500 1 Oct. 2018-
 6AV6640-0AA00-0AX1 TD 400C Basic Panel P.M410 1 Oct. 2019G
 6ES7272-0AA30-0YA0 TD 200 6ES7272-0AA30-0YA1 P.M490 1 Oct. 2017G
 6ES7272-0AA30-0YA1 TD 200 Basic Panel P.M410 1 Oct. 2020G
 6ES7272-1AA10-0YA0 TD 200C 6ES7272-1AA10-0YA1 P.M490 1 Oct. 2018G
 6ES7272-1AA10-0YA1 TD 200C Basic Panel P.M490 1 Oct. 2020 G
 6ES7272-1BA10-0YA0 TD 100C 6ES7272-1BA10-0YA1 P.M490 1 Oct. 2017 G
 6ES7272-1BA10-0YA1 TD 100C Basic Panel P.M490 1 Oct. 2022 U
 6AV3503-1DB10 OP3 Basic Panel P.M500 1 Oct. 2018 W
 6AV3607-1JC00-0AX1 OP7 6AV3607-1JC00-0AX2 P.M500 1 Oct. 2018 R
 6AV3607-1JC00-0AX2 OP7 Basic Panel P.M500 1 Oct. 2018 U
 6AV3607-1JC20-0AX1 OP7 6AV3607-1JC20-0AX2 P.M500 1 Oct. 2018 R
 6AV3607-1JC20-0AX2 OP7 Basic Panel P.M500 1 Oct. 2018 U
 6AV3607-1JC30-0AX1 OP7 6AV3607-1JC30-0AX2 P.M500 1 Oct. 2018 R
 6AV3607-1JC30-0AX2 OP7 Basic Panel P.M500 1 Oct. 2018 U
 6AV3617-1JC00-0AX1 OP17 6AV3617-1JC00-0AX2 P.M500 1 Oct. 2018 R
 6AV3617-1JC00-0AX2 OP17 Basic Panel P.M500 1 Oct. 2018 U
 6AV3617-1JC20-0AX1 OP17 6AV3617-1JC20-0AX2 P.M500 1 Oct. 2018 R
 6AV3617-1JC20-0AX2 OP17 Basic Panel P.M500 1 Oct. 2018 U
 6AV3617-1JC30-0AX1 OP17 6AV3617-1JC30-0AX2 P.M500 1 Oct. 2018 R
 6AV3617-1JC30-0AX2 OP17 Basic Panel P.M500 1 Oct. 2018 U
 6AV6545-0AA15-2AX0 TP070 Basic Panel P.M490 1 Apr. 2017 U
 6AV6640-0BA11-0AX0 OP73micro Basic Panel P.M410 1 Oct. 2020 W
 6AV6641-0AA11-0AX0 OP73 Basic Panel P.M410 1 Oct. 2020 W
 6AV6641-0BA11-0AX0 OP77A 6AV6641-0BA11-0AX1 P.M490 30 June 2015 W
 6AV6641-0BA11-0AX1 OP77A Basic Panel P.M410 1 Oct. 2020 W
 6AV6641-0CA01-0AX0 OP77B 6AV6641-0CA01-0AX1 P.M500 1 Oct. 2017 -
 6AV6641-0CA01-0AX1 OP77B Comfort PanelVSF since 1 Jan. 2015 W
 6AV6640-0DA11-0AX0 K TP178micro 6AV6648-0AC11-3AX0 P.M500 1 Oct. 2014 -
 6AV6640-0CA01-0AX0 TP170micro Basic Panel P.M490 1 Oct. 2016 U
 6AV6640-0CA11-0AX0 TP177micro 6AV6640-0CA11-0AX1 P.M490 1 Oct. 2016 W
 6AV6640-0CA11-0AX1 TP177micro Basic Panel P.M410 8 Aug. 2018 U
 6AV6545-0BA15-2AX0 TP170A Basic Panel P.M490 1 Apr. 2017 U
 6AV6545-0BB15-2AX0 TP170B_M Basic Panel P.M490 1April 2017 U
 6AV6545-0BC15-2AX0 TP170B_C Basic Panel P.M490 1 Apr. 2017 U
 6AV6642-0AA11-0AX0 TP177A 6AV6642-0AA11-0AX1 P.M500 1 Oct. 2017 G
 6AV6642-0AA11-0AX1 TP177A Basic Panel P.M410 8 Aug. 2018 U
 6AV6642-0BD01-3AX0 TP177B 4" Comfort Panel VSF since 1 Jan. 2015 W
 6AV6642-0BC01-1AX0 TP177B DP 6AV6642-0BC01-1AX1 P.M490 1 Oct. 2016 W
 6AV6642-0BC01-1AX1 TP177B DP Comfort Panel VSF since 1 Jan. 2015 U
 6AV6642-0BA01-1AX0 TP177B PN/DP 6AV6642-0BA01-1AX1 P.M490 1 Oct. 2016 W
 6AV6642-0BA01-1AX1 TP177B PN/DP Comfort Panel VSF since 1 Jan. 2015 W
 6AV6542-0BB15-2AX0 OP170B Basic Panel P.M410 1 Oct. 2016 U
 6AV6642-0DA01-1AX0 OP177B PN/DP 6AV6642-0DA01-1AX1 P.M490 1 Oct. 2016 W
 6AV6642-0DA01-1AX1 OP177B PN/DP Comfort Panel VSF since 1 Jan. 2015 W
 6AV6642-0DC01-1AX0 OP177B DP 6AV6642-0DC01-1AX1 P.M490 1 Oct. 2016 G
 6AV6642-0DC01-1AX1 OP177B DP Comfort Panel VSF since 1 Jan. 2015 U
 6AV6545-0CA10-0AX0 TP270 6" 6AV6545-0CA10-0AX1 P.M490 1 Oct. 2017 U
 6AV6545-0CA10-0AX0 TP270 6" Basic Panel P.M490 1 Oct. 2017 U
 6AV6545-0CC10-0AX0 TP270 10" Basic Panel P.M490 1 Oct. 2017 U
 6AV6542-0CA10-0AX0 OP270 6" 6AV6542-0CA10-0AX1 P.M490 1 Oct. 2017 R
 6AV6542-0CA10-0AX1 OP270 6" Basic Panel P.M490 1 Oct. 2017 U
 6AV6542-0CC10-0AX0 OP270 10" Basic Panel P.M490 1 Oct. 2017 U
 6AV6643-0AA01-1AX0 TP277 6" Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0BA01-1AX0 OP277 6" Comfort Panel VSF since 1 Jan. 2015 W
 6AV6642-0EA01-3AX0 MP177 6"  Comfort Panel  VSF since 1 Jan. 2015 W
 6AV6545-0AH10-0AX0 MP270B 6" 6AV6545-0AH10-0AX1 P.M490 1 Oct. 2016 U
 6AV6545-0AH10-0AX1 MP270B 6" Basic Panel P.M490 26 June 2018 U
 6AV6542-0AG10-0AX0 MP270B 10"K Basic Panel P.M490 1 Oct. 2017 U
 6AV6545-0AG10-0AX0 MP270B 10"T Basic Panel P.M490 1 Oct. 2017 U
 6AV6643-0CB01-1AX0 MP277 8"T 6AV6643-0CB01-1AX1 P.M490 1 Oct. 2016 W
 6AV6643-0CB01-1AX1 MP277 8"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0CB01-1AX2 MP277 8"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0CB01-1AX5 MP277 8"T Comfort Panel  P.M490 1 Oct. 2016 U
 6AV6643-0CD01-1AX0 MP277 10"T 6AV6643-0CD01-1AX1 P.M490 1 Oct. 2016 W
 6AV6643-0CD01-1AX1 MP277 10"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0CD01-1AX2 MP277 10"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0CD01-1AX5 MP277 10"T Comfort Panel P.M490 1 Oct. 2016 U
 6AV6643-0DB01-1AX0 MP277 8"K 6AV6643-0DB01-1AX1 P.M490 1 Oct. 2016 U
 6AV6643-0DB01-1AX1 MP277 8"K Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0DB01-1AX2 MP277 8"K Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0DB01-1AX5 MP277 8"K Comfort Panel P.M490 1 Oct. 2016 W
 6AV6643-0DD01-1AX0 MP277 10"K 6AV6643-0DD01-1AX1 P.M490 1 Oct. 2016 W
 6AV6643-0DD01-1AX1 MP277 10"K Comfort Panel VSF since 1 Jan. 2015 W
 6AV6643-0DD01-1AX2 MP277 10"K Comfort Panel VSF since 1 Jan. 2015 W
 6AV6542-0DA10-0AX0 MP370 12"K Comfort Panel P.M490 1 March 2018 U
 6AV6545-0DA10-0AX0 MP370 12"T Comfort Panel P.M490 1 March 2018 U
 6AV6545-0DB10-0AX0 MP370 15"T Comfort Panel P.M490 1 March 2018 U
 6AV6644-0AA01-2AX0 MP377 12"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6644-0AB01-2AX0 MP377 15"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6644-0AC01-2AX0 MP377 19"T 6AV6644-0AC01-2AX1 P.M490 1 Oct. 2016 W
 6AV6644-0AC01-2AX1 MP377 19"T Comfort Panel VSF since 1 Jan. 2015 W
 6AV6644-0BA01-2AX0 MP377 12"K 6AV6644-0BA01-2AX1 P.M490 1 Oct. 2016 W
 6AV6644-0BA01-2AX1 MP377 12"K Comfort Panel VSF since 1 Jan. 2015 W
 6AV6644-2AB01-2AX0  MP377 PRO 15" Touch Panel P.M400 1 Jan. 2016 W
6AV66715CE000AX1
Mobile Panel 277 IWLAN CHARGING STATION MOBILE PANEL 277(F) IWLAN V2 P.M410 1 Oct. 2018 W
6AV66450DD010AX1Mobile Panel 277 IWLAN  MOBILE PANEL 277 IWLAN V2P.M410  1 Oct. 2018 W
 6AV66450DD020AX1Mobile Panel 277 IWLAN MOBILE PANEL 277 IWLAN V2 (EU VERSION) P.M410  1 Oct. 2018 W
 6AV66450DE010AX1Mobile Panel 277 IWLAN MOBILE PANEL 277 IWLAN V2 P.M410  1 Oct. 2018 W
6AV66450DE020AX1Mobile Panel 277 IWLAN  MOBILE PANEL 277 IWLAN V2  (EU VERSION) P.M410  1 Oct. 2018 W
 6AV66450FD010AX1Mobile Panel 277 IWLAN MOBILE PANEL 277 IWLAN V2 (USA VERSION) P.M410  1 Oct. 2018 W
 6AV66450FE010AX1Mobile Panel 277 IWLAN MOBILE PANEL 277 IWLAN V2 (USA VERSION) P.M410  1 Oct. 2018 W
 6AV66450GF010AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN (RFID TAG/USA) P.M410  1 Oct. 2018 W
 6AV66450EB010AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 P.M410  1 Oct. 2018 W
 6AV66450EB020AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 (EU VERSION) P.M410  1 Oct. 2018 W
 6AV66450EC010AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 P.M410  1 Oct. 2018 W
 6AV66450EC020AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 (EU VERSION) P.M410  1 Oct. 2018 W
 6AV66450EF010AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 (RFID TAG) P.M410  1 Oct. 2018 W
 6AV66450EF020AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 (RFID TAG) (EU VERSION) P.M410  1 Oct. 2018 W
 6AV66450GB010AX1Mobile Panel 277F IWLAN MOBILE PANEL 277F IWLAN V2 (USA VERSION) P.M410  1 Oct. 2018 W
 6AV66450GC010AX1Mobile Panel 277F IWLAN  MOBILE PANEL 277F IWLAN V2 (USA VERSION) P.M410  1 Oct. 2018 W
 6AV6671-5CM00-0AX1 Transponder No successor available P.M410 1 Oct. 2018 W
 6AV6671-5CE00-0AX1 Charging station No successor available P.M410 1 Oct. 2018 W
 6AV21241QC020AX0
 KP1500 Comfort 6AV21241QC020AX1VSF start on 1 Oct. 2018 W
 6AV21240QC020AX0 TP1500 Comfort 6AV21240QC020AX1VSF start on 1 Oct. 2018 W
 6AV21240UC020AX0 TP1900 Comfort 6AV21240UC020AX1VSF start on 1 Oct. 2018 W
 6AV21240XC020AX0 TP2200 Comfort 6AV21240XC020AX1VSF start on 1 Oct. 2018 W
 6AV66450BA010AX0  Mobile Panel 177 PN  +ZT SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66450BB010AX0  Mobile Panel 177 PN  +ZT+ST SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66450BC010AX0 Mobile Panel 177 PN  + ZT+ST+HR+SS+LDT SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66450AB010AX0 Mobile Panel 177 DP  +ZT+ST SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66450AA010AX0 Mobile Panel 177 DP  +ZT SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66450AC010AX0 Mobile Panel 177 DP  + ZT+ST+HR+SS+LDT SIMATIC HMI KTP700 Mobile, 7.0" P.M410 1 Oct. 2019 W
 6AV66715AE110AX0 PN Plus connection box SIMATIC HMI connection box  P.M410 1 Oct. 2026  G
 6AV66715AE010AX0 PN Basic connection box SIMATIC HMI connection box  P.M410 1 Oct. 2026  G
 6AV66715AE100AX0 DP Plus connection box SIMATIC HMI connection box  P.M410 1 Oct. 2026  G
 6AV66715AE000AX0 DP Basic connection box SIMATIC HMI connection box  P.M410 1 Oct. 2026  G

Legend:
P.M400 -  Phase-out code. Start of the spare parts period
P.M410 - Product available as spare part only
VSF - Product available as spare part only
P.M490 - Product warranty - No new parts and spare parts available any longer!
P.M500 - Product will be completely deleted, afterwards it can no longer be identified!

Spare parts information:

W - Spare part, replacement and/or repair possible, When the defective device is returned, the customer will receive a credit to the amount specified according to the Wxx. W55 means, for example, that the credit is 55 % of the spare part price after the device has been returned.
U - Replacement only (exceptions are permitted only upon prior written justification; for further information, contact your Siemens representative) 
R - Repair only
G - Spare part purchase possible - cannot be repaired

The spare parts information is only valid until P.M490 is reached. It becomes irrelevant when P.M490 is reached.

Pricing information

Price changes
All products which have reached PM400 or higher are affected; an annual 10 % price increase typically applies here.

For products with the status "VSF since", an annual 10 % price increase typically applies for new parts.
The price for spare parts having the same article number increased by 100 % on 1 October 2017 (credit on return of the defective device). This measure was necessary to reduce the circumvention of the registration for the new parts warehouse. This measure means for all customers that the supply of spare parts will be guaranteed until at least 1 October 2022. For all products with the status "VSF since", TIA Portal version V14 provides adequate Comfort Panels which offer much higher efficiency, performance and more favorable prices than the existing Classic Panels listed here.

Example for a product with returned goods code W55

Case A: If you buy the new part, you pay € 1000
Case B: € 2000 must be paid for freely available spare parts. When returning the defective device, you will receive a credit note. The amount of credit is based on the spare parts code and the overall condition of the defective part, see also the graphic below.





Our objective, for our customers:

1. Long-term availability of spare parts for all customers worldwide, from around 2008 to 2026
2. Best investment protection for all end customers that use our HMI and other Siemens products
3. Long-term planning security through contracts for registered customers
4. None of our competitors guarantees comprehensive spare parts availability and 100% compatibility over 10 years
5. Understandable price transparency, no need for end customers to stock up on products
5. Lowest plant downtimes, spare parts are available 24/7, when necessary with 24h express delivery service (for an additional charge / region-dependent)

ATEX note for Classic Panels:
All Classic Panels with ATEX standard EN60079-0:2006 will not be migrated to the new standard EN60079-0:2012. The  ATEX Standard EN60079-0:2006  is still valid. All applications requiring the new standard must be migrated to the relevant successor. Important: The ATEX standard must always be stated on the rating plate of the device. All devices may only be used in ATEX environments if they are provided with the relevant label.

Marine certificates:
Existing certificates are not renewed after their expiration for products as of and including P.M490. For inventory in the field (already in use), existing certificates will remain valid!

Product successor

Our current products from the Basic Panel and Comfort Panel range are available as product successors.
As the current devices offer much higher efficiency, greater functionality and thereby more performance, it is not possible to make a general statement about the successors.

It is always advisable to select the successor based on the requirements of the application. Various migration aids are available to help you make a decision.

Link to the topic of general migration 76878921 

Advantages of system migration 73051526 

Basic Panels migration guideline 64790503 

Comfort Panels migration guideline 49752044

If you have further questions, please contact your Siemens representative or find additional information on the topic of migration here  76878921 .

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.