Firmware Update for ET200pro CPU 1516pro F-2 PN

  • 寄稿
  • 製品に関係する
This entry contains all firmware versions for the ET200pro CPU 1516pro F-2 PN. - Latest change: new firmware version V2.9.2

Description:

When firmware is updated, it must always be updated to the latest version available for the relevant article number. The previous versions of the firmware are only intended as a backup to enable you to downgrade to the original version, although this has never been known to be necessary.
The respective latest version of a firmware is valid for all versions of that article number.

How to update the firmware is described in detail in entry ID 77492231.

Overview of article numbers and firmware versions of the ET200pro CPU 1516pro F-2 PN:
Please note: The software is subject to export restrictions; the download is only available to registered users

 Article number

Firmware version

Update with ...

6ES7516-2GN00-0AB0  
 V2.9.2
Release 07.05.2021 

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files Multilingual_ReadMe_OSS_V292 respectively ReadMe_OSS_en_US_V292.

Special information for resellers

The information and the license terms in the files Multilingual_ReadMe_OSS_V292 respectively ReadMe_OSS_en_US_V292 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  Multilingual_ReadMe_OSS_V292.html (2,2 MB)
 Registrierung notwendig  ReadMe_OSS_en_US_V292.html (2,2 MB)
 Registrierung notwendig  OpenSourceSoftware_V292.ZIP (93,0 MB)(SHA-256)
(Information on SHA-256)


Recommended for update:
For a description, see below Update V2.9.2

Please note: The software is subject to export restrictions; the download is only available to registered users
 Download unterliegt Exportcontrolle  6ES7516-2GN00-0AB0_V292.ZIP (24,0 MB)(SHA-256)
(Information on SHA-256

 V2.8.3
Release 22.07.2020

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files Multilingual_ReadMe_OSS_V283 respectively ReadMe_OSS_en_US_V283.

Special information for resellers

The information and the license terms in the files Multilingual_ReadMe_OSS_V283 respectively ReadMe_OSS_en_US_V283 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  Multilingual_ReadMe_OSS_V283.htm (3,2 MB)
 Registrierung notwendig  ReadMe_OSS_en_US_V283.htm (3,2 MB)


Backup only:
For a description, see below Update V2.8.3

Please note: The software is subject to export restrictions; the download is only available to registered users
 Download unterliegt Exportcontrolle  6ES7516-2GN00-0AB0_V283.ZIP (22,9 MB)

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V283.txt (1 KB) 

 V2.8.2
Release 02.04.2020

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files Multilingual_ReadMe_OSS_V282 respectively ReadMe_OSS_en_US_V282.

Special information for resellers

The information and the license terms in the files Multilingual_ReadMe_OSS_V282 respectively ReadMe_OSS_en_US_V282 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  Multilingual_ReadMe_OSS_V282.htm (4,9 MB)
 Registrierung notwendig  ReadMe_OSS_en_US_V282.htm (4,8 MB)


Backup only:
For a description, see below Update V2.8.2

Please note: The software is subject to export restrictions; the download is only available to registered users
 Download unterliegt Exportcontrolle  6ES7516-2GN00-0AB0_V282.ZIP (22,9 MB)

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V282.txt (1 KB)

 V2.8.1
Release 14.11.2019

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files Multilingual_ReadMe_OSS_V280_V281 respectively   ReadMe_OSS_en_US_V280_V281.

Special information for resellers

The information and the license terms in the files Multilingual_ReadMe_OSS_V280_V281 respectively   ReadMe_OSS_en_US_V280_V281 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  Multilingual_ReadMe_OSS_V280_V281.htm (4,9 MB)
 Registrierung notwendig  ReadMe_OSS_en_US_V280_V281.htm (4,8 MB)


Backup only:
For a description, see below Update V2.8.1

Please note: The software is subject to export restrictions; the download is only available to registered users
 Download unterliegt Exportcontrolle  6ES7516-2GN00-0AB0_V281.ZIP (22,8 MB)

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V281.txt (1 KB) 

 V2.6.1
Release 04.04.2019

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files 2016_Readme_OSS_Global_V14_V261 and   ReadMe_OSS_en_US_V261.

Special information for resellers

The information and the license terms in the files 2016_Readme_OSS_Global_V14_V261 and ReadMe_OSS_en_US_V261 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  2016_Readme_OSS_Global_V14_V261.htm (5,1 MB)
 Registrierung notwendig  ReadMe_OSS_es_ES_V261.htm (5,1 MB) 


Backup only:
For a description, see below Update V2.6.1
 Registrierung notwendig  6ES7516-2GN00-0AB0_V261.ZIP (22,3 MB) 

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V261.txt (1 KB) 

 V2.6.0
Release 12.10.2018

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the files 2016_Readme_OSS_Global_V14_V260 and   ReadMe_OSS_en_US_V260.

Special information for resellers

The information and the license terms in the files 2016_Readme_OSS_Global_V14_V260 and ReadMe_OSS_en_US_V260 must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  2016_Readme_OSS_Global_V14_V260.htm (5,1 MB) 
 Registrierung notwendig  ReadMe_OSS_en_US_V260.htm (5,1 MB) 


Backup only:
For a description, see below Update V2.6.0
 Registrierung notwendig  6ES7516-2GN00-0AB0_V260.ZIP (22,3 MB) 

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V260.txt (1 KB)

 V2.5.2
Release 27.04.2018

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the Readme_OSS_CPU_S7-1500_V252 file.

Special information for resellers

The information and the license terms in the Readme_OSS_CPU_S7-1500_V252 file must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  ReadMe_OSS_CPU_S7-1500_V252.rtf (11,3 MB)


Backup only:
For a description, see below Update V2.5.2
 Registrierung notwendig  6ES7516-2GN00-0AB0_V252.ZIP (21,8 MB)

SHA-256 checksum ( Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V252.txt (1 KB)

 V2.5.0
Release 15.12.2017

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the Readme_OSS_CPU_S7-1500_V250 file.

Special information for resellers

The information and the license terms in the Readme_OSS_CPU_S7-1500_V250 file must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  ReadMe_OSS_CPU_S7-1500_V250.rtf (11,3 MB)


Backup only:
For a description, see below Update V2.5.0
 Registrierung notwendig  6ES7516-2GN00-0AB0_V250.ZIP (21,8 MB)

SHA-256 checksum (Information on SHA-256)
 Registrierung notwendig  6ES7516-2GN00-0AB0_V250.txt (1 KB)

 V2.1.0
Release 24.03.1017

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the Readme_OSS_V210 file.

Special information for resellers

The information and the license terms in the Readme_OSS_V210 file must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  ReadMe_OSS_V210.htm (3,0 MB)


Backup only:
For a description, see below Update V2.1.0
 Registrierung notwendig  6ES7516-2GN00-0AB0_V210.ZIP (18,1 MB)

 V2.0.5
Release 03.02.2017

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the Readme_OSS_V205 file.

Special information for resellers

The information and the license terms in the Readme_OSS_V205 file must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  ReadMe_OSS_V205.htm (3,0 MB)


Backup only:
For a description, see below Update V2.0.5
 Registrierung notwendig  6ES7516-2GN00-0AB0_V205.ZIP (17,9 MB)

 V2.0.3
Release 16.12.2016

Third-party software - Licensing terms and copyright information

You can find the copyright information for third-party software contained in this product, particularly open source software, as well as applicable licensing terms of such third-party software in the Readme_OSS_V203 file.

Special information for resellers

The information and the license terms in the Readme_OSS_V203 file must be passed on to the purchasing party to avoid license infringements by the reseller or purchasing party.

 Registrierung notwendig  ReadMe_OSS_V203.htm (3,0 MB)


Backup only:
For a description, see below Update V2.0.3
 Registrierung notwendig  6ES7516-2GN00-0AB0_V203.ZIP (17,9 MB)

 V2.0.1
Release 21.10.2016
Backup only:
 Registrierung notwendig  6ES7516-2GN00-0AB0_V201.ZIP (17,9 MB) 


Update V2.8.3 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7, STEP 7 Safety Advanced and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V17 or higher is required to configure this CPU firmware version. 
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163 

You can find details on firmware version V2.9.2 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.8.3 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7, STEP 7 Safety Advanced and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V16 or higher is required to configure this CPU firmware version. 
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163 

You can find details on firmware version V2.8.3 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.8.2 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7, STEP 7 Safety Advanced and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V16 or higher is required to configure this CPU firmware version. 
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163 

You can find details on firmware version V2.8.2 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.8.1 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7, STEP 7 Safety Advanced and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V16 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163 

You can find details on firmware version V2.8.1 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.6.1 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V15.1 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163 

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V15.1 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

You can find details on firmware version V2.6.1 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.6.0 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V15.1 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.
The handling is described detailed in entry 109744163

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V15.1 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

You can find details on firmware version V2.6.0 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.5.2 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V15 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V15 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

You can find details on firmware version V2.5.2 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.5.0 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V15 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V15 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

You can find details on firmware version V2.5 in the entry Firmware update S7-1500 CPUs incl. displays and ET 200 CPUs (ET 200SP, ET 200pro) 


Update V2.1.0 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V14 SP1 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V14 SP1 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

New feature with firmware V2.1:

  • A consistent upload of fail-safe projects is supported as of STEP 7 Safety V14 SP1.


New features with firmware V2.1 during programming:

  • Via the instruction "GetSMCInfo", you can read out the card size, the memory space which is already occupied on the memory card, and the number of write/delete processes performed on the card in the user program.
  • In order to be able to split up or further process control words and status words, elementary data types can be converted into a bit-array using the "SCATTER" instruction and a bit-array converted into an elementary data type, such as WORD, using the "GATHER" instruction.

The following behavior has been changed with FW 2.1:

  • In the event of a peripheral access error, direct peripheral accesses, which are interconnected as input parameters to components, have no longer the result that the component is no longer run through. Instead of this, the system uses the replacement value of the signal in the component.

The following behavior has been revised with FW 2.1:

  • When monitoring a component online, the CPU does no longer STOP on account of area length errors.
  • When generating alarm text using the "Get_Alarm" block, the behavior regarding alarm texts has been improved.
  • With the "Get_Alarm" block, the status message "W#16#8003 – the parameter Lcid is invalid or a language selected at the parameter Lcid is not loaded" is no longer output if the "InfoText" parameter is empty with the "Alarm_Data" data type.
  • The behavior of the "Get_Alarm" has been improved regarding the call from several OB priorities.
  • The behavior of the "STP" instruction, when simultaneously performing "online monitoring" via the TIA Portal, has been improved.
  • The behavior shown when downloading data logs via the webserver of the CPU has been improved.
  • When performing "online monitoring" of blocks, the behavior that the TIA Portal freezes during scrolling if this block is called from several OBs having different priority, does no longer occur.
  • The start behavior of the OPC UA server, in particular with large data volumes, has been improved.

The following behavior has been corrected with FW 2.1:

  • The CPU does no longer go to STOP when copying large structures using the instruction "MOV_BLK_VARIANT".
  • The following sporadic message “Serious firmware exception error (non user-relevant system code: 16#00000000 16#10020000 16#00000000)“ does no longer occur if a large number of diagnostic events is reported via the AS-i.


Update V2.0.5 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V14 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V14 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.

The following behavior has been revised with FW 2.0.5:

  • If, when online monitoring a block, the message (0604:000255) “Insufficient resources are available for the "Monitoring" function“ is output, you can still access the CPU as soon as sufficient resources are available.
  • The function of the SPLIT command in conjunction with structures comprising two or more sub-structures has been improved.
  • When using the DPWR_DAT or DPRD_DAT command in two OBs featuring different priorities, inconsistent data storages do no longer occur highly sporadically when using the command in the low-priority OB.
  • If the CPU is significantly loaded during Motion Control applications, a CPU STOP may occur due to an overflow of MC-Interpolator (OB92) respectively MC-Servo (OB91).
    During the subsequent CPU RUN, uncontrolled axis movements do no longer occur sporadically.


Update V2.0.3 (6ES7516-2GN00-0AB0)

Dependencies with regard to STEP 7 and upwards compatibility:
Totally Integrated Automation Portal with STEP 7 Professional V14 or higher is required to configure this CPU firmware version.
Configurations with earlier TIA Portal STEP 7 Professional versions are compatible with later releases.

Dependencies with regard to STEP 7 Safety Advanced and upwards compatibility:
In addition, the option package STEP 7 Safety Advanced V14 or later is required to configure safety integrated applications with this firmware version of the failsafe CPU.
Configurations with earlier STEP7 Safety Advanced versions are compatible with later releases.


The following behavior has been corrected with FW 2.0.3:

  • The following sporadic message: "Serious firmware exception error

    (non user-relevant system code: 16#400001 16#10020074 16#4a6c24d0)“ does no longer occur if a ProcessEvent OB is triggered by various ProcessEvents having different priorities, such that it interrupts itself.

  • The following sporadic message "Serious firmware exception error
    (non user-relevant system code: 16#400001 16#10020011 16#468a6be8)“ does no longer occur
    if the “DataLogWrite“ block is used in the user program.

  • The following sporadic message "Serious firmware exception error
    (non user-relevant system code: 16#00400001 16#1002012E 16#00010206)“ does no longer occur if, during an active connection setup via T_CON using a CM1542-1/CP1543-1, the connection is already closed via T_DISCON.


The following behavior has been changed with FW 2.0.3:

  • The security behavior of the CPUs has been improved 
  • The TIA Portal is no longer frozen if the memory card of the CPU is filled by the trace functions.
  • The behavior of the blocks “DPRD_DAT“ and “RD_REC“ in combination with optimized data blocks has been improved.
セキュリティ情報
技術的なインフラストラクチャー、システム、機械とネットワークをサイバー脅威から守るために、現在の技術の状態に応じた全体的なITセキュリティーコンセプトを実装すること(そして持続的に維持すること)が必要です。シーメンスの製品とソリューションはそのようなコンセプトの1つの要素だけを形成します。サイバーセキュリティーについての詳細は以下をご覧ください:
https://www.siemens.com/cybersecurity#Ouraspiration.
寄稿を評価する
評価なし
リクエストとフィードバック
何をしたいですか?
注: フィードバックは常に現在のエントリ / 製品に関連しています。メッセージは、オンラインサポートで作業しているテクニカルエディタに転送されます。フィードバックに応答が必要な場合は、数日以内に返信いたします。これ以上問題がない場合、ご連絡はいたしません。
統計に対するサポート
この機能によって、希望する数に基づく検索結果のIDが出力されます (format .txt)

Generate list
URL をコピーする
このページを新しいデザインで表示する
mySupport コックピット