×
Siemens Industry Online Support
Siemens AG
Entry ID: 109742709, Entry date: 12/03/2018
(3)
Rate

Documentation for the distributed I/O system ET 200SP

  • Entry
The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas.





Basic information

The system manual describes, among other things, system properties, assembly, wiring and commissioning. The product information contains up-to-date information and supersedes other statements in the documentation. The STEP 7 online help supports you in the configuration and programming.

SIMATIC ET 200SP Distributed I/O system
SIMATIC ET 200SP Product information on the documentation of the ET 200SP distributed I/O system
SIMATIC ET 200SP PROFIenergy product information
SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL
SIMATIC ET 200SP User calibration of analog modules
SIMATIC ET 200SP Open Controller Product information on CPU 1515SP PC2 (F/T/TF)
ET 200SP Distributed I/O System - Fail-Safe Modules
SIMATIC ET 200SP Product Information for the Documentation of ET 200SP Fail-safe Modules
SIMATIC STEP 7 Basic/Professional V15.1 and SIMATIC WinCC V15.1


Device Information 

Product manuals contain a compact description of the module-specific information, such as properties, wiring diagrams, characteristics and technical specifications.

CPUs

SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)
SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)
SIMATIC ET 200SP Open Controller CPU 1515SP PC (F)
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (F/T/TF)
SIMATIC S7-1200/S7-1500 F-CPUs

Interface modules

SIMATIC ET 200SP IM 155-6 PN BA interface module (6ES7155-6AR00-0AN0)
SIMATIC ET 200SP IM 155-6 PN ST Interface Module (6ES7155-6AU00-0BN0)
SIMATIC ET 200SP interface module IM 155-6 PN/2 HF (6ES7155-6AU00-0CN0)
SIMATIC ET 200SP IM 155-6 PN HS Interface Module (6ES7155-6AU00-0DN0)
SIMATIC ET 200SP IM 155-6 DP HF interface module (6ES7155-6BA00-0CN0)
SIMATIC ET 200SP interface module IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)
SIMATIC ET 200SP server module (6ES7193-6PA00-0AA0)

Digital modules

SIMATIC ET 200SP digital input module DI 8x24VDC BA (6ES7131-6BF00-0AA0)
SIMATIC ET 200SP digital input module DI 8x24VDC ST (6ES7131-6BF00-0BA0)
SIMATIC ET 200SP digital input module DI 8x24VDC HS (6ES7131-6BF00-0DA0)
SIMATIC ET 200SP Digital Input Module DI 8x24VDC HF (6ES7131-6BF00-0CA0)
SIMATIC ET 200SP DI 8x24VDC ST Digital Input Module (6ES7131-6BF60-0AA0)
SIMATIC ET 200SP DI 8xNAMUR HF digital input module (6ES7131-6TF00-0CA0)
SIMATIC ET 200SP digital input module I 8x24VAC/48VUC BA (6ES7131-6CF00-0AU0)
SIMATIC ET 200SP Digital Input Module DI 16x24VDC ST (6ES/131-6BH00-0BA0)
SIMATIC ET 200SP digital input module DI 4x120..230VAC ST (6ES7131-6FD00-0BB1)
SIMATIC ET 200SPDigital input module F-DI 8x24VDC HF (6ES7136-6BA00-0CA0)


SIMATIC ET 200SP Digital Output Module DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0)
SIMATIC ET 200SP digital output module DQ 4x24VDC/2A HS (6ES7132-6BD20-0DA0)
SIMATIC ET 200SP Digital Output Module DQ 4x24VDC/2A HF  (6ES7132-6BD20-0CA0)
SIMATIC ET 200SP DQ 4x24..230VAC/2A ST digital output module  (6ES7132-6FD00-0BB1)
SIMATIC ET 200SP Digital Output Module DQ 4x24..230VAC/2A HF (6ES7132-6FD00-0CU0)
SIMATIC ET 200SP Digital Output Module DQ 8x24VDC/0.5A BA  (6ES7132-6BF00-0AA0)
SIMATIC ET 200SP digital output module DQ 8x24VDC/0.5A ST (6ES7132-6BF00-0BA0)
SIMATIC ET 200SP Digital Output Module DQ 8x24VDC/0.5A HF (6ES7132-6BF00-0CA0)
SIMATIC ET 200SP Digital Output Module DQ 8x24VDC/0.5A SNK BA (6ES7132-6BF60-0AA0)
SIMATIC ET 200SP Digital Output Module DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0)
SIMATIC ET 200SP Digital Output Module DQ 16x24VDC/0.5A BA (6ES7132-6BH00-0AA0)
SIMATIC ET 200SP Digital Output Module RQ 4x120VDC-230VAC/5A NO ST (6ES7132-6HD00-0BB1)
SIMATIC ET 200SP Digital Output Module RQ 4x120VDC-230VAC/5A NO MA ST (6ES7132-6MD00-0BB1)
SIMATIC ET 200SP digital output module RQ 4x24VUC/2A CO ST (6ES7132-6GD50-0BA0)
SIMATIC ET 200SP Digital output module F-DQ 4x24VDC/2A PM HF (6ES7136-6DB00-0CA0)
SIMATIC ET 200SP Digital output module F-RQ 1x24VDC/24..230VAC/5A (6ES7136-6RA00-0BF0)
SIMATIC ET 200SP Digital Output Module F-DQ 8x24VDC/0.5A PP HF (6ES7136-6DC00-0CA0)

Analog modules

SIMATIC ET 200SP Analog Input Module AI 2xU ST (6ES7134-6FB00-0BA1)
SIMATIC ET 200SP Analog Input Module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1)
SIMATIC ET 200SP analog input module AI 2xU/I 2-/4-wire HS (6ES7134-6HB00-0DA1)
SIMATIC ET 200SP Analog Input Module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)
SIMATIC ET 200SP analog input module AI 4xU/I 2-wire ST (6ES7134-6HD00-0BA1)
SIMATIC ET 200SP analog input module AI 4xI 2-/4-wire ST (6ES7134-6GD00-0BA1)
Analog Input Module AI 4xI 2-wire 4…20mA HART
SIMATIC ET 200SP analog input module AI 4xRTD/TC 2-/3-/4-wire HF (6ES7134-6JD00-0CA1)
SIMATIC ET 200SP analog input module AI 8xU BA (6ES7134-6FF00-0AA1)
SIMATIC ET 200SP analog input module AI 8xI 2-/4-wire BA (6ES7134-6GF00-0AA1)
SIMATIC ET 200SP analog input module AI 8xRTD/TC 2-wire HF (6ES7134-6JF00-0CA1)
SIMATIC ET 200SP Analog Input Module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0)
SIMATIC ET 200SP Analog Input Module AI Energy Meter 480VAC ST (6ES7134-6PA20-0BD0)
SIMATIC ET 200SP analog input module AI Energy Meter 480VAC/CT HF (6ES7134-6PA00-0CU0)
SIMATIC ET 200SP analog input module AI Energy Meter 480VAC/RC HF (6ES7134-6PA20-0CU0)
SIMATIC ET 200SP product information on the "Analog input module AI Energy Meter 480VAC/CT HF" and "Analog input module AI Energy Meter 480VAC/RC HF" device manuals
SIMATIC ET 200SP analog input module F-AI 4xI 0(4)..20mA 2-/4-wire HF (6ES7136-6AA00-0CA1)


SIMATIC ET 200SP Analog Output Module AQ 2xI ST (6ES7135-6GB00-0BA1)
SIMATIC ET 200SP Analog Output Module AQ 2xu ST (6ES7135-6FB00-0BA1)
SIMATIC ET 200SP analog output module AQ 2xU/I HS (6ES7135-6HB00-0DA1)
SIMATIC ET 200SP analog output module AQ 2xU/I HF (6ES7135-6HB00-0CA1)
SIMATIC ET 200SP analog output module AQ 4xU/I ST (6ES7135-6HD00-0BA1)
SIMATIC ET 200SP analog input module AI 4xTC HS (6ES7134-6JD00-0DA1)

Technology modules

SIMATIC ET 200SP TM Count 1x24V (6ES7138-6AA00-0BA0)
SIMATIC ET 200SP TM PosInput 1 (6ES7138-6BA00-0BA0)
SIMATIC ET 200SP Technology module TM Pulse 2x24V (6ES7138-6DB00-0BB1)(6ES7138-6DB00-0BB1)
SIMATIC ET 200SP Technology module TM Timer DIDQ 10x24V (6ES7138-6CG00-0BA0)(6ES7138-6CG00-0BA0)
SIWAREX WP321 electronic weighing system

Communication modules

SIMATIC ET 200SP communication module CM DP (6ES7545-5DA00-0AB0)
SIMATIC ET 200SP CM PtP (6ES7137-6AA00-0BA0)
SIMATIC NET ET 200SP - Industrial Ethernet CP 154xSP-1
SIMATIC ET 200SP communication module IO-Link master CM 4xIO-Link (6ES7137-6BD00-0BA0)
Manual - CM AS-i Master ST for SIMATIC ET 200SP (3RK7137-6SA00-0BC1)
Manual F-CM AS-i Safety ST Module for SIMATIC ET 200SP

Power modules

SIMATIC ET 200SP Power Module F-PM-E 24VDC/8A PPM ST (6ES7136-6PA00-0BC0)
SIMATIC ET 200SP Product Information for the documentation on Power Module F-PM-E 24VDC/8A PPM ST (6ES7136-6PA00-0BC0)

BaseUnits

SIMATIC ET 200SP BaseUnits

BusAdapter

SIMATIC BusAdapter

 

Network transitions

SIMATIC Bus links PN/PN coupler



General informations

The function manuals contain detailed descriptions on general topics regarding the SIMATIC S7-1500 and ET 200MP systems, e.g. diagnostics, communication, motion control, Web server, OPC UA.

CPU function modules

SIMATIC S7-1500, S7-1500R/H, ET 200SP, ET 200pro Cycle and response times
SIMATIC S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory
SIMATIC S7-1500, ET 200SP, ET 200pro Web server
SIMATIC S7-1500 S7-PLCSIM Advanced
Readme SIMATIC S7-PLCSIM Advanced V2.0 SP1

Diagnostics function manuals

SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL, ET 200pro Diagnostics
SIMATIC / SINAMICS S7-1500, S7-1200 / S120, G120 Using the trace and logic analyzer function

Communication function manuals

SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL, ET 200pro Communication
SIMATIC PROFINET PROFINET with STEP 7 V15
SIMATIC PROFIBUS PROFIBUS with STEP 7 V13
CM PtP - Configurations for point-to-point connections
CM PtP operation with PROFINET controller

I/O function manuals

SIMATIC IO-Link system
SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL, ET 200pro, ET 200eco PN Analog value processing
SIMATIC High-precision input/output with Time-based IO
SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL Designing interference-free controllers

Technology function manuals

SIMATIC S7-1500 S7‑1500 Motion Control V4.0 in TIA Portal V15
SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL Counting, measurement and position detection
SIMATIC Industrial Software SIMATIC Safety - Configuring and Programming
SIMATIC S7-1200, S7-1500 PID control


Manual Collection ET 200SP

The Manual Collection contains the complete documentation on the ET 200SP distributed I/O system gathered together in one pdf file.

SIMATIC ET 200SP Manual Collection