What spare parts are there for which mounting unit?

  • Entry
  • Associated product(s)
Artikel-Nummer:A5E42151886A
Revision002
Datum17.07.2019
 


 Monting element Spare part 
NrMLFBNameOrder no.Name
17MH4133-3DC11BB 10 ... 200 kg
Combination mounting unit
A5E39102915Pendulum bolt for 7MH4133-3DC11
27MH4133-3DC11BB 10 ... 200 kg
Combination mounting unit
A5E39111139Gasket for
7MH4133-3DC11
37MH4135-4DC11SB 0.5 ... 2 t
Combination mounting unit
A5E39111190Pendulum bolt for 7MH4135-4DC11, 7MH5707-4AA00 and 7MH5707-4GA00
47MH4135-4DC11SB 0.5 ... 2 t
Combination mounting unit
A5E39111198Gasket for
7MH4135-4DC11
57MH4135-4KC11SB 5 t
Combination mounting unit
A5E39111223Pendulum bolt for 7MH4135-4KC11 and 7MH5707-4PA00
67MH4135-4KC11SB 5 t
Combination mounting unit
A5E39111382Gasket for
7MH4135-4KC11
77MH4115-3DB11RN 60 ... 280 kg
Top unit
A5E39111688Pendulum bolt for 7MH4115-3DB11, 7MH4125-3DA11 and 7MH5713-3JA00 
87MH4115-3DB11RN 60 ... 280 kg
Top unit
A5E39111729Gasket for
7MH4115-3DB11 and 7MH4125-3DA11
97MH4125-3DA11RN 60 ... 280 kg
Combination mounting unit
A5E39111688Pendulum bolt for 7MH4115-3DB11, 7MH4125-3DA11 and 7MH5713-3JA00 
107MH4125-3DA11RN 60 ... 280 kg
Combination mounting unit
A5E39111729Gasket for
7MH4115-3DB11 and 7MH4125-3DA11
117MH4132-4AK11RN 0.5 / 1 t
Top unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
127MH4132-4AK11RN 0.5 / 1 t
Top unit
A5E39111850Gasket for
7MH4132-4AK11 and 7MH4132-4AC11
137MH4132-4AC11RN 0.5 / 1 t
Combination mounting unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
147MH4132-4AC11RN 0.5 / 1 t
Combination mounting unit
A5E39111850Gasket for
7MH4132-4AK11 and 7MH4132-4AC11
157MH4132-4KK11RN 2 ... 5 t
Top unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
167MH4132-4KK11RN 2 ... 5 t
Top unit
A5E39111937Gasket for
7MH4132-4KK11 and 7MH4132-4KC11
177MH4132-4KC11RN 2 ... 5 t
Combination mounting unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
187MH4132-4KC11RN 2 ... 5 t
Combination mounting unit
A5E39111937Gasket for
7MH4132-4KK11 and 7MH4132-4KC11
197MH4115-5BB11RN 10 / 13 t
Top unit
A5E39115863Pendulum bolt for 7MH4115-5BB11, 7MH4125-5BA11 and 7MH5713-5DA00
207MH4115-5BB11RN 10 / 13 t
Top unit
A5E39115882Gasket for
7MH4115-5BB11 and 7MH4125-5BA11
217MH4125-5BA11RN 10 / 13 t
Combination mounting unit
A5E39115863Pendulum bolt for 7MH4115-5BB11, 7MH4125-5BA11 and 7MH5713-5DA00
227MH4125-5BA11RN 10 / 13 t
Combination mounting unit
A5E39115882Gasket for
7MH4115-5BB11 and 7MH4125-5BA11
237MH5707-4AA00 SB-S SA 0.5 / 1 t
Compact mounting unit
A5E39111190Pendulum bolt for 7MH4135-4DC11, 7MH5707-4AA00 and 7MH5707-4GA00
247MH5707-4GA00 SB-S SA 2 t
Compact mounting unit
A5E39111190Pendulum bolt for 7MH4135-4DC11, 7MH5707-4AA00 and 7MH5707-4GA00
257MH5707-4PA00 SB-S SA 5 t
Compact mounting unit
A5E39111223Pendulum bolt for 7MH4135-4KC11 and 7MH5707-4PA00
267MH5713-3JA00  RN-S SA 60 ... 280 kg
Compact mounting unit
A5E39111688Pendulum bolt for 7MH4115-3DB11, 7MH4125-3DA11 and 7MH5713-3JA00 
277MH5713-3JA00  RN-S SA 60 ... 280 kg
Compact mounting unit
A5E39116622Shim M8 for
7MH5713-3JA00 
287MH5713-4AA00   RN-S SA 0.5 / 1 t
Compact mounting unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
297MH5713-4AA00   RN-S SA 0.5 / 1 t
Compact mounting unit
A5E39116633Shim M10 for
7MH5713-4AA00 and 7MH5713-4PA00
307MH5713-4PA00   RN-S SA 2 ... 5 t
Compact mounting unit
A5E39111815Pendulum bolt for 7MH4132-4AK11, 7MH4132-4KK11, 7MH4132-4AC11, 7MH4132-4KC11, 7MH5713-4AA00, 7MH5713-4PA00
317MH5713-4PA00   RN-S SA 2 ... 5 t
Compact mounting unit
A5E39116633Shim M10 for
7MH5713-4AA00 and 7MH5713-4PA00
327MH5713-5DA00   RN-S SA 10 / 13 t
Compact mounting unit
A5E39115863Pendulum bolt for 7MH4115-5BB11, 7MH4125-5BA11 and 7MH5713-5DA00
337MH5713-5DA00   RN-S SA 10 / 13 t
Compact mounting unit
A5E39116745Shim M12 for
7MH5713-5DA00
347MH4133-3DC11BB 10 ... 200 kg
Combination mounting unit
A5E39222174Enlosure for pendulum bolt for
7MH4133-3DC11
357MH5713-3JA00RN-S SA 60kg ... 280kg Compact mounting unitA5E41564707Pressure piece for
7MH5713-3JA00
367MH5713-4AA00RN-S SA 500kg/1t
Compact mounting unit
A5E41564829Pressure piece for
7MH5713-4AA00
377MH4115-5DB11RN-S SA 28t
Self-aligning bearing top part
A5E47960304Pendulum bolt set for
7MH4115-5DB11 
387MH4115-5GB11RN-S SA 60t
Self-aligning bearing top part
A5E47960363Pendulum bolt set for
7MH4115-5GB11

 


Support to the statistics