Siemens Industry Online Support
Siemens AG
Entry type: Product note Entry ID: 109748857, Entry date: 07/13/2017
(0)
Rate

Sales and delivery approval for SIMATIC PCS 7 Minerals Automation Standard CEMAT V9.0

  • Entry
  • Associated product(s)
SIMATIC PCS 7 Minerals Automation Standard CEMAT V9.0, the innovative control system for the cement, building materials and mining industries, is released in its 9.0 version based on SIMATIC PCS 7 V9.0.

PCS 7 Minerals Automation Standard CEMAT (MinAS / CEMAT) covers all aspects of the complete production chain from the extraction of the raw materials to the packaging of the final product. In addition, PCS 7 Minerals Automation Standard CEMAT includes various additional modules, e.g. for milling optimization by means of Advanced Process Control (APC) functions or Scalable Production Control (SPC) for prescription processes.



Existing MinAS/CEMAT projects with version 6.1 / 7.x and V8.x can be upgraded to the new version.

New features and expansions with the MinAS/CEMAT V9.0

  • New interlock module with two input
  • Zoom for the faceplates
  • PCS 7 standard measuring point browser and standard curve compilation can be used with MinAS/CEMAT
  • Consistent visualization of active bypasses at valves, flaps and drives
  • Open faceplates from the maintenance list directly
  • Expansions for SPC, e.g.
    • The material manager is now cascadable
    • AS-spanning use of the material manager
    • A new prescription module for binary values
    • Expanded prescription approval function
    • and incorporation of operating authorizations
  • MinAS/CEMAT is now available as SUS

Compatibility

MinAS/CEMAT V9.0 needs SIMATIC PCS 7 V9.0 as a prerequisite. When upgrading to MinAS/CEMAT V9.0, current project data are retained. Do not fail to read the product information contained on the software DVD before installing the upgrade.

Ordering information for SIMATIC PCS 7 Minerals Automation Standard CEMAT V9.0

DesignationArticle number
MinAS/CEMAT Engineering Software
MinAS/CEMAT V9.0 - Engineering
Engineering V9.0 Software, 2 languages (German, English), operating systems
according to SIMATIC PCS 7 System V9.0
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 436-8AX58-0XA0
MinAS/CEMAT OS software for single station including AS runtime licenses (PLC)
MinAS/CEMAT V9.0 - Single Station (3 AS)
OS V9.0 Software Single Station Runtime incl. 3 AS Runtime licenses (PLC),
2 languages (German, English), operating systems according to SIMATIC PCS 7
System V9.0
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 434-8AA58-0XA0
MinAS/CEMAT OS Software for Client 
MinAS/CEMAT V9.0 - Client
OS V9.0 Software Client Runtime, in 2 languages (German, English),
operating systems according to SIMATIC PCS 7 System V9.0, Single
License for 1 installation
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 435-8AX58-0XA0
MinAS/CEMAT OS software for redundant server including AS runtime licenses (PLC)

MinAS/CEMAT V9.0 - Server Redundancy (3 AS)
OS V9.0 Software Runtime for redundant server pair including runtime licenses
for 6 AS (PLC), 2 languages (German, English), operating systems according
to SIMATIC PCS 7 Server V9.0, single license for 2 installations
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 

6DL5 433-8AA58-0XA0
MinAS/CEMAT V9.0 - Server Redundancy (6 AS)
OS V9.0 Software Runtime for redundant server pair including runtime licenses
for 6 AS (PLC), 2 languages (German, English), operating systems according
to SIMATIC PCS 7 Server V9.0, single license for 2 installations
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 433-8AB58-0XA0
MinAS/CEMAT V9.0 - Server Redundancy (9 AS)
OS V9.0 Software Runtime for redundant server pair including runtime licenses
for 9 AS (PLC), 2 languages (German, English), operating systems according
to SIMATIC PCS 7 Server V9.0, single license for 2 installations
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 433-8AC58-0XA0
MinAS/CEMAT V9.0 - Server Redundancy (unlimited AS)
OS V9.0 Software Runtime for redundant server pair including runtime licenses
for unlimited AS (PLC), 2 languages (German, English), operating systems
according to SIMATIC PCS 7 Server V9.0, single license for 2 installations
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
 
6DL5 433-8AD58-0XA0
MinAS/CEMAT OS PowerPacks for redundant server pair 
(to expand the AS runtime licenses)
OS PowerPack for redundant server pair, for expansion of the AS Runtime licenses, 2 languages (German, English), executable under Windows 7 Ultimate/Enterprise SP1 (32/64 Bit) or Windows Server 2008 R2 Standard SP1 (64 Bit), Single License for 2 installations
Type of delivery: 2 License Key USB sticks, Certificate of License
MinAS/CEMAT V9.0 - Server Red. PowerPack (3 AS -> 6 AS)
For expansion of runtime licenses from 3 to 6 AS
 
6DL5 433-8AB58-0XD0
MinAS/CEMAT V9.0 - Server Red. PowerPack (6 AS -> 9 AS)
For expansion of runtime licenses from 6 to 9 AS
 
6DL5 433-8AC58-0XD0
MinAS/CEMAT Server Redundancy (unlimited) V9.0
For expansion of runtime licenses from 9 to unlimited AS
 
6DL5 433-8AD58-0XD0

MinAS/CEMAT Software Upgrade to version 9.0

Existing installations MinAS / CEMAT V6.x, V7.x and V8.x can be upgraded with the MinAS/CEMAT Software Upgrade V9.0 package. This must be ordered in the required quantity before the upgrade. You can order it from your regional Siemens sales partner under the following order number.

For an upgrade of MinAS/CEMAT V6.x, V7.x and V8.x each engineering station, OS server and OS single station requires a MinAS/CEMAT software upgrade V9.0.

The upgrade can only be used together with a valid MinAS/CEMAT license. There is no authorization check on the basis of the license number of your upgradeable product.

Product nameArticle number
MinAS/CEMAT V9.0 - Upgrade Package
Engineering and runtime Software, 2 languages (German, English),
operating systems according to SIMATIC PCS 7 System V9.0, single license
for 1 installation
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
Can only be used together with a valid CEMAT license.
 
6DL5 430-8AX58-0XE0

Software Update Service (SUS)

As an alternative to the MinAS/CEMAT V9.0 upgrade package, you can order an Update Service (SUS) for SIMATIC PCS 7 Minerals Automation Standard CEMAT V9.0. This is required in the same number as the upgrade package.

Product nameArticle number
MinAS/CEMAT Software Update Service
Engineering and runtime Software, 2 languages (German, English),
operating systems according to SIMATIC PCS 7 System V9.0, single license
for 1 installation
Delivery form: package:
Software and electronic documentation in 2 languages (German and English)
on DVD, License Key USB Stick, Certificate of License
Can only be used together with a valid CEMAT license.
 

6DL5433-1XX00-0YL8

The duration of the SUS is initially limited to one year. If you do not cancel the SUS up to 3 months before expiry, the term will be automatically extended by another year. After expiration of the first year, the software update service will be billed regularly. You will find more information on the Software Update Service (SUS) in the SIMATIC PCS 7 V9.0 catalog, Section 1. (Catalog PCS 7 V9.0 comming soon) 

Customer Support

Siemens offers Service & Support at each project phase: from the planning stage through commissioning to maintenance and modernization. For an overview of the complete performance spectrum, visit:

http://www.siemens.com/automation/csi_de_WW/service (national)
http://www.siemens.com/automation/csi_en_WW/service (international)

For CEMAT you can request the support of our Technical Support (Hotline) from Industry Automation and Drive Technologies via the Support Request procedure:

http://www.siemens.com/automation/csi_de_WW/support_request (national)
http://www.siemens.com/automation/csi_en_WW/support_request (international)

For a clear product allocation, please always state the keyword "CEMAT" in your support request. If the product assignment is not clearly identifiable, delays can occur during processing. 

Further information about MinAS/CEMAT

Further information about MinAS/CEMAT is available at the following address

http://www.siemens.com/Cemat

and

http://www.siemens.com/MinAS


Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.
Rate entry
no rating
Requests and feedback
What do you want to do?