The new version is now available for delivery with SIMATIC PCS 7 PowerControl V9.0. It correlates with the SIMATIC PCS 7 V9.0 process control system. The new version offers more improvements regarding usability.

1. Information material

Information and order data for SIMATIC SIMATIC PCS 7 PowerControl V9.0 is available in the Industry Mall as well as the next edition of the ST PCS 7 T catalog, SIMATIC PCS 7 Process Control System, Technology Components, section "Switchgear automation".

Detailed information for integration of switchgear in process industries is available in the SIMATIC PCS 7 PowerControl brochure.

  • Brochure in German: Article number E86060-A4678-A331-A1
  • Brochure in English: Article number E86060-A4678-A331-A1-7600

2. Ordering data

2.1. Components for PCS 7 PowerControl Engineering Station V9.0

DesignationArticle number
PCS 7 PowerControl OS Engineering Software
PCS 7 PowerControl OS Engineering V9.0 (PO unlimited)
for expansion of an SIMATIC PCS 7 Engineering Station V9.0 (PO unlimited) with PCS 7 PowerControl V9.0;

Software package without SIMATIC PCS 7 Engineering software V.9.0, 2 languages (German, English), software class A, runs with Windows 7 Ultimate/Enterprise
32/64-bit, Windows 10 Enterprise 2015 LTSB 64-bit, Windows Server 2012 R2 Standard 64-bit, floating license for 1 user

Electronic documentation on DVD 2 languages (English, German)

Type of delivery
License key memory stick, certificate of license and DVD 
"PCS 7 PowerControl V9.0"
 
6ES7658-7LX58-0YA5
   

2.2. Components for PCS 7 PowerControl Operator System V9.0

DesignationArticle number
PCS 7 PowerControl OS Runtime Software
PCS 7 PowerControl OS Runtime V9.0
PCS 7 PowerControl OS Runtime software with PCS 7 PowerControl IEC 61850 driver to expand a SIMATIC PCS 7 OS V9.0 (server/single station) with PCS 7 PowerControl V9.0; software package without SIMATIC PCS 7 OS software V9.0
   
Runtime software, 2 languages (German, English), software class A, runs with Windows 7 Ultimate/Enterprise 32/64-bit, Windows 10 Enterprise 2015 LTSB
64-bit, Windows Server 2012 R2 Standard 64-bit, single license for 1 installation
  
Electronic documentation on DVD 2 languages (English, German)

Type of delivery
License key memory stick, certificate of license and DVD 
"PCS 7 PowerControl V9.0" 
 
6ES7658-7MX58-0YA0
   

2.3. Components for PCS 7 PowerControl libraries V9.0

DesignationArticle number

PCS 7 PowerControl Library

PCS 7 PowerControl Library V9.0

AS blocks, symbols and faceplates for integrating electrical equipment (intelligent electronic devices) via a StationController/StationGateway.


Engineering software, software class A, 2 languages (German, English), runs with Windows 7 Ultimate/Enterprise 32/64-bit, Windows 10 Enterprise 2015 LTSB
64-bit, Windows Server 2012 R2 Standard 64-bit, single license for 1 installation, valid for one AS or a station controller.


Type of delivery

Package (without SIMATIC PCS 7 Software Media Package)

  • Certificate of License
  • Software and electronic documentation in 2 languages (German and English) on DVD
  
6ES7658-7NX58-2YA0
PCS 7 PowerControl PROFIBUS DP Driver Library

PCS 7 PowerControl PROFIBUS DP Driver Library V9.0

AS driver blocks for integrating SIPROTEC protection devices on PROFIBUS DP.


Runtime software, software class A, 2 languages (German, English), runs with Windows 7 Ultimate/Enterprise 32/64-bit, Windows 10 Enterprise 2015 LTSB
64-bit, Windows Server 2012 R2 Standard 64-bit, single license for 1 installation, valid for one AS


Type of delivery

Package (without SIMATIC PCS 7 Software Media Package)

  • Certificate of License
  • Software and electronic documentation in 2 languages (German and English) on DVD


    6ES7658-7PX58-2YA0
         

    2.3. PCS 7 PowerControl OS Upgrade Package V8.x to V9.0

    Note
    SIMATIC PCS 7 ES and OS software V8.x included in some software packages must be upgraded to V9.0 using separate upgrade packages. 

      

    DesignationArticle number
    PCS 7 PowerControl OS Upgrade Package

    PCS 7 PowerControl OS Upgrade Package V8.x to V9.0

    Software package without SIMATIC PCS 7 ES/OS software V9.0

    2 languages (German, English), software class A, runs with Windows 7 Ultimate/Enterprise 32/64-bit, Windows 10 Enterprise 2015 LTSB 64-bit, Windows Server 2012 R2 Standard 64-bit, single license for 1 installation


    Type of delivery
    License key memory stick, certificate of license and DVD
    "PCS 7 PowerControl V9.0"
     
    6ES7652-5JX58-0YE0
       

    2.4. PCS 7 PowerControl Library Upgrade Package V8.x to V9.0

    DesignationArticle number
    PCS 7 PowerControl Library Upgrade Package

    PCS 7 PowerControl Library Upgrade Package V8.x to V9.0

    AS blocks, symbols and faceplates for integrating electrical equipment (intelligent electronic devices) via station controller/station gateway. 

    Engineering software, software class A, 2 languages (German, English), runs with Windows 7 Ultimate/Enterprise 32/64-bit, Windows 10 Enterprise 2015 LTSB
    64-bit, Windows Server 2012 R2 Standard 64-bit, single license for 1 installation, valid for one AS or a station controller.


    Type of delivery

    Package (without SIMATIC PCS 7 Software Media Package)

    • Certificate of License
    • Software and electronic documentation in 2 languages (German and English) on DVD 
    6ES7652-5JX58-2YE0
       

    3. Expansion components for PCS 7 PowerControl

    The standard products for PCS 7 PowerControl listed above can be expanded with the following components for specific projects:

    • Basic library for PCS 7 PowerControl
      (CFC blocks for IEC 61850 communication for S7-400 controller)
    • Station controller for PCS 7 PowerControl (incl. IEC 61850 communication library "SC_DRV")

    • Station gateway for SIMATIC PCS 7 PowerControl (incl. communication library "SG_LINK")

      Additional information
       
      Siemens AG
      DF CS PA PFM
      Karlsruhe
      Mr. Daniel Müller
      E-mail: mueller.dm@siemens.com
        

      4. Service und Support

      Industry Online Support
      Do you have any questions or need assistance?
      Siemens Industry Online Support offers round the clock access to our entire service and support know-how and portfolio.

      The Industry Online Support is the central address for information about our products, solutions and services.

      Product information, manuals, downloads, FAQs, and application examples – all the information you need is accessible with just a few mouse clicks at: https://support.industry.siemens.com
        
      Technical Support
      The Technical Support of Siemens Industry provides you fast and competent support regarding all technical queries with numerous tailor-made offers – ranging from basic support to individual support contracts.
        
      You send queries to Technical Support via Web form: 
      www.siemens.com/industry/supportrequest
        
      Service offer
      Our range of services includes, inter alia, the following:

      • Product trainings
      • Plant data services

      • Spare parts services

      • Repair services

      • On-site and maintenance services

      • Retrofitting and modernization services

      • Service programs and contracts

      You can find detailed information on our range of services in the service catalog: https://support.industry.siemens.com/cs/sc

      Industry Online Support app
      You will receive optimum support wherever you are with the "Siemens Industry Online Support" app. The app is available for Apple iOS, Android and Windows Phone:  
      https://support.industry.siemens.com/cs/ww/en/sc/2067
        

      Security information
      In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
      https://www.siemens.com/cybersecurity#Ouraspiration.