Siemens Industry Online Support
Siemens AG
Entry type: Application example Entry ID: 109762735, Entry date: 03/28/2019
(10)
Rate

SIMATIC Safe Kinematics – Getting Started

  • Entry
  • Associated product(s)
SIMATIC Safe Kinematics allows you to monitor kinematic movements safely. This Getting Started shows you exemplary how to commission and configure SIMATIC Safe Kinematics on the control and drive side.



Prerequisites

  • SIMATIC Safe Kinematics
  • TIA Portal V15.1
  • STEP 7 Safety Advanced
  • CPU 1517TF-3 PN/DP
  • SINAMICS S120 from FW 5.1

Downloads
  Manual SIMATIC Safe Kinematics Getting Started (2,7 MB) 
 Registrierung notwendig  TIA Add-In for Safe Kinematics (216,5 KB)


Videos
In addition to the manual, we also offer you the option of viewing the individual steps for commissioning and configuring SIMATIC Safe Kinematics in four videos.

Chapter 1: Engineering of drives
The video shows you the most important steps for setting up the user project in the TIA Portal, adding the SIMATIC controller and the SINAMICS drive to the TIA Portal project, setting up the data exchange between controller and drive, adding the technology objects for the drive axes in the SIMATIC controller and activating the Safety functions in the drive.





Chapter 2: Setup safe homing in the drives
The video shows you the integration of the required libraries "LAcycCom" and "LDrvSafe" and the call of the library blocks in the user program.





Chapter 3: Isochronous safe communication between drives and controller
The video shows how to set up the required isochronous safety program for safe position transfer from the drive to the controller.





Chapter 4: Library integration SIMATIC Safe Kinematics in the user program
The video shows how to set up the kinematics to be monitored. A roll picker kinematics is used as example. The video shows the definition of the monitoring zones, the calling of the function blocks for linking the kinematics to the functions of "Safe Kinematics" and the transfer of the data of the technology object to the data storage of "Safe Kinematics" with the help of a TIA Add-In.



Additional Keywords
motioncontrol_apc_applications

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit