Medium-voltage components

  • Entry
Highly available, efficient power supply for outdoor or indoor use with vacuum technology. Our switchboards and devices are used in power plants and transforming stations, distribution substations, transformer substations or utility substations, on ships or in trains - one series of our medium-voltage components can be used for IEC and UL markets and for up to 120,000 operating cycles.


Medium voltage

Medium voltage refers to the range from 1 kV to 52 kV (alternating voltage). These voltages are usually used for distribution and industrial power systems.

Medium-voltage components

They include numerous circuit breakers (for up to 120,000 operating cycles) and reclosers, switchgear such as circuit breakers (for IEC and UL markets), switches, switching contactors, busbar section disconnectors, switch disconnectors and ground switches and non-switching equipment, such as fuses, instrument transformers and surge arresters and surge limiters.

Our comprehensive portfolio

Our portfolio of vacuum switching technology for installation in air-insulated medium-voltage switchgear and gas-insulated medium-voltage switchgear (GIS) ensures reliable and safe power distribution at all times.



SION vacuum circuit breakers (IEC, UL)

3TM/3TL vacuum contactors Arresters

SION 3AE5

SION 3AE6

SION 3AE1

3TM1, 3TM3

3TL


3EF

3EJ


Vacuum circuit breakers for special applications (IEC, UL)Vacuum interrupters

High-current switching applications

Generator switching applications

Frequent operations (with up to 120,000 operating cycles)

Traction applications

For circuit breakers

For contactors

For switch disconnectors

For reclosers



Configurator for medium-voltage vacuum circuit breakers and vacuum contactors

 

Link>> on "Configurators" tab


Download

3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE53
Unit wiring diagram for SION Circuit Breakers 3AE1, 3AE2, 3AE5 and 3AE6
Unit wiring diagram for Circuit Breakers 3AH3, 3AH4 and 3AK7
Unit wiring diagram for Circuit Breakers 3AK7
3D-models, 2D-dimension drawings and unit wiring diagrams for SION Circuit Breakers 3AE5
3D-data for vacuum circuit breaker 3AK7
3D-models for vacuum circuit breaker 3AH3
3D-data for vacuum circuit breaker 3AH4
3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE615
3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE617
3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE613
3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE616
3D-models, 2D-dimension drawings for SION Circuit Breakers 3AE618
More downloads in the Siemens Industry Online Support


Manuals

SION - Vacuum circuit-breaker (7.2 kV - 17.5 kV, 16 kA - 40 kA / 24 kV, 16 kA - 25 kA) - valid for products with delivery from 08/2019
SION Lateral - Vacuum circuit-breaker (12 kV - 24 kV / 12.5 kA - 25 kA) - valid for products with delivery from 04/2019
3TM 1-pole Vacuum contactor (4.15 kV – 6.9 kV)
3TM Vacuum contactor (7.2 kV – 12 kV)
SION - Vacuum circuit-breaker (7.2 kV - 17.5 kV, 16 kA - 31.5 kA / 24 kV, 16 kA - 25 kA) - valid for products with delivery until 07/2019
SION Lateral - Vacuum circuit-breaker (12 kV - 24 kV / 12.5 kA - 25 kA) - valid for products with delivery until 03/2019
More manuals in the Siemens Industry Online Support

Catalogs


Catalog HG 11.21 • 2019 - 3TL Vacuum Contactors
Flyer - 3TM vacuum contactors - Safe switching of operational currents in medium-voltage power distribution
Technical portfolio information - SION 3AE5 vacuum circuit breakers
Catalog HG 11.03 • 2018 - 3AH3 Vacuum Circuit-Breakers
Catalog HG 11.02 • 2020 - SION Vacuum Circuit Breaker 3AE5
Catalog HG 11.04 • 2018 - 3AH4 Vacuum Circuit-Breakers
Quick Selection Guide - SION 3AE vacuum circuit breakers
Catalog HG 11.07 • 10/2018 - SION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism
Brochurre - Vacuum circuit breakers for generator switching applications
Surge arrester 3EK8
Catalog HG 11.06 • 2017 - 3AK7 Vacuum Circuit-Breakers
Catalog HG 11.05 • 2017 - 3AH5 Vacuum Circuit-Breakers
Catalog HG 11.52 • 2017 - 3AH47 Vacuum Circuit-Breakers for Traction Applications
Catalog HP-AR 41 - Surge arresters for railway applications
Catalog HG 11.01 • 2016 - Vacuum Switching Technology and Components for Medium Voltage
Surge arrester - Fundamentals
More catalogs in the Siemens Industry Online Support



Characteristics

Tripping characteristics, TOV characteristic surge arrester, 3EK7030-4CB0, 3EK7210-4CD0, 3EK7300-4CF0, 3EB4



Service & Support

Assistance with technical queries is provided at
Information in the Industry Online Support

You can find your local contact at

Contacts database

Support requests

Our product specialists are available to answer your technical queries at

www.siemens.com/lowvoltage/support-request



Certificates 

Test certificate
General product approval
Manufacturer's declaration