Siemens Industry Online Support
Siemens AG
Entry type: Product note Entry ID: 109780632, Entry date: 03/10/2021
(1)
Rate

SIMATIC S7-1200: Push-in terminal blocks available as spare part kits

  • Entry
  • Associated product(s)
The SIMATIC S7-1200 product range is being expanded by terminal strip spare part kits in push-in technology. These terminals blocks are suitable for all standard and fail-safe CPUs and associated signal modules of the SIMATIC S7-1200.

The push-in terminal block spare part kits are offered in addition to existing similar screw-type versions. They come in the same packaging unit (4 units per package) and can be used optionally as alternative connectors.

Order data of CPU terminal blocks:

S7-1200 Standard CPU
(Article number) 
Terminal block 
 Screw-type
Article number 
Matching Push-in Type
Article number
 Description

 CPU 1211C DC/DC/DC
 (6ES7211-1AE40-0XB0)

 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH30-0XA0 6ES7292-2AH30-0XA0 8-pin, tin-coated
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA0 14-pin, tin-coated
 CPU 1211C DC/DC/Relay   (6ES7211-1HE40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH40-0XA0 6ES7292-2AH40-0XA0 8-pin, tin-coated, coded
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA0 14-pin, tin-coated
 CPU 1211C AC/DC/Relay   (6ES7211-1BE40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH40-0XA0 6ES7292-2AH40-0XA0 8-pin, tin-coated, coded
 6ES7292-1AP40-0XA0 6ES7292-2AP40-0XA0 14-pin, tin-coated, coded
 CPU 1212C DC/DC/DC
 (6ES7212-1AE40-0XB0)
 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH30-0XA0 6ES7292-2AH30-0XA0 8-pin, tin-coated
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA014-pin, tin-coated
 CPU 1212C DC/DC/Relay   (6ES7212-1HE40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH40-0XA0 6ES7292-2AH40-0XA0 8-pin, tin-coated, coded
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA0 14-pin, tin-coated
 CPU 1212C AC/DC/Relay   (6ES7212-1BE40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH40-0XA0 6ES7292-2AH40-0XA0 8-pin, tin-coated, coded
 6ES7292-1AP40-0XA0 6ES7292-2AP40-0XA0 14-pin, tin-coated, coded
 CPU 1214C DC/DC/DC
 (6ES7214-1AG40-0XB0)
 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AM30-0XA0 6ES7292-2AM30-0XA0 12-pin, tin-coated
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
 CPU 1214C DC/DC/Relay   (6ES7214-1HG40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
 CPU 1214C AC/DC/Relay   (6ES7214-1BG40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV40-0XA0 6ES7292-2AV40-0XA0 20-pin, tin-coated, coded
 CPU 1215C DC/DC/DC
 (6ES7215-1AG40-0XB0)
 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AM30-0XA0 6ES7292-2AM30-0XA0 12-pin, tin-coated
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
 CPU 1215C DC/DC/Relay   (6ES7215-1HG40-0XB0) 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
 CPU 1215C AC/DC/Relay   (6ES7215-1BG40-0XB0) 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV40-0XA0 6ES7292-2AV40-0XA0 20-pin, tin-coated, coded
 CPU 1217C DC/DC/DC
 (6ES7217-1AG40-0XB0)
 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AK30-0XA0 6ES7292-2AK30-0XA0 10-pin, tin-coated
 6ES7292-1AR30-0XA0 6ES7292-2AR30-0XA0 16-pin, tin-coated
 6ES7292-1AT30-0XA0 6ES7292-2AT30-0XA0 18-pin, tin-coated


S7-1200 Fail Safe CPU 
(Article number) 
Terminal block 
 Screw-type 
Article number 
Matching Push-in Type 
Article number
 Description

CPU 1212FC DC/DC/DC 
 (6ES7212-1AF40-0XB0)

 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA03-pin, gold-plated
 6ES7292-1AH30-0XA0 6ES7292-2AH30-0XA08-pin, tin-coated
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA0 14-pin, tin-coated
CPU 1212FC DC/DC/Relay   (6ES7212-1HF40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AH40-0XA0 6ES7292-2AH40-0XA0 8-pin, tin-coated, coded
 6ES7292-1AP30-0XA0 6ES7292-2AP30-0XA0 14-pin, tin-coated
CPU 1214FC DC/DC/DC 
 (6ES7214-1AF40-0XB0)
 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AM30-0XA0 6ES7292-2AM30-0XA0 12-pin, tin-coated
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
CPU 1214FC DC/DC/Relay   (6ES7214-1HF40-0XB0) 6ES7292-1BC30-0XA0 6ES7292-2BC30-0XA0 3-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
CPU 1215FC DC/DC/DC 
 (6ES7215-1AF40-0XB0)
 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AM30-0XA0 6ES7292-2AM30-0XA0 12-pin, tin-coated
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated
CPU 1215FC DC/DC/Relay   (6ES7215-1HF40-0XB0) 6ES7292-1BF30-0XB0 6ES7292-2BF30-0XB0 6-pin, gold-plated
 6ES7292-1AM40-0XA0 6ES7292-2AM40-0XA0 12-pin, tin-coated, coded
 6ES7292-1AV30-0XA0 6ES7292-2AV30-0XA0 20-pin, tin-coated


Order data of terminals for digital signal modules:
S7-1200 Digital Signal Modules 
(Article number) 
Terminal block 
 Screw-type  
Article number 
Matching Push-in Type 
Article number  
 SM 1221 DI 8 x DC
 (6ES7221-1BF32-0XB0)
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 SM 1221 DI 16 x DC
(6ES7221-1BH32-0XB0) 
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 SM 1222 DQ 8 x DC
 (6ES7222-1BF32-0XB0)
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 SM 1222 DQ 8 x Relay
 (6ES7222-1HF32-0XB0)
 6ES7292-1AG40-0XA1 6ES7292-2AG40-0XA1
 SM 1222 DQ 16 x DC
 (6ES7222-1BH32-0XB0)
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 SM 1222 DQ 16 x Relay
 (6ES7222-1HH32-0XB0)
 6ES7292-1AG40-0XA0  6ES7292-2AG40-0XA0
 SM 1222 DQ 8 x Relay (Changeover)(6ES7222‑1XF32‑0XB0) 6ES7292-1AL40-0XA0 6ES7292-2AL40-0XA0
 SM 1223 DI 8 x DC/DQ 8 x DC        (6ES7223-1BH32-0XB0) 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 SM 1223 8 x DC/8 x Relay               (6ES7223-1PH32-0XB0) 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0
 6ES7292-1AG40-0XA0 6ES7292-2AG40-0XA0
 SM 1223 8 x AC/8 x Relay               (6ES7223-1QH32-0XB0) 6ES7292-1AG40-0XA0 6ES7292-2AG40-0XA0
 SM 1223 DI 16 x DC/DQ 16 x DC    (6ES7223-1BL32-0XB0) 6ES7292-1AL30-0XA0 6ES7292-2AL30-0XA0
 SM 1223 DI 16 x DC/DQ 16 x Relay   (6ES7223-1PL32-0XB0) 6ES7292-1AL30-0XA0 6ES7292-2AL30-0XA0
 6ES7292-1AL40-0XA0 6ES7292-2AL40-0XA0


S7-1200 Fail Safe Digital Signal Modules 
(Article number) 
Terminal block 
 Screw-type  
Article number 
Matching Push-in Type 
Article number  
 SM 1226 F-DI 16x 24VDC                (6ES7226-6BA32-0XB0)  6ES7292-1AL30-0XA0 6ES7292-2AL30-0XA0
 SM 1226 F-DQ 4x 24VDC                                 (6ES7226-6DA32-0XB0) 6ES7292-1AL30-0XA0 6ES7292-2AL30-0XA0
 SM 1226 F-DQ 2x Relay                                   (6ES7226-6RA32-0XB0) 6ES7292-1AL40-0XA0 6ES7292-2AL40-0XA0


Order data of terminals for analog signal modules:

S7-1200 Analog Signal Modules 
(Article number) 
Terminal block 
Screw-type 
Article number 
Matching Push-in Type 
Article number  
 Description
 SM 1231 AI 4 x 13 bit 
 (6ES7231-4HD32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 4 x 16 bit
 (6ES7231-5ND32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 8 x 13 BIT
 (6ES7231-4HF32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 4 x TC
 (6ES7231-5QD32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 8 x TC
 (6ES7231-5QF32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 4 x RTD
 (6ES7231-5PD32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1231 AI 8 x RTD
 (6ES7231-5PF32-0XB0)
 6ES7292-1BL30-0XA0  6ES7292-2BL30-0XA0 11-pin, gold-plated
 SM 1232 AQ 2 x 14 bit
 (6ES7232-4HB32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1232 AQ 4 x 14 bit
 (6ES7232-4HD32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated

 SM 1234 AI 4 / AQ 2 

 (6ES7234-4HE32-0XB0)
 6ES7292-1BG30-0XA0 6ES7292-2BG30-0XA0 7-pin, gold-plated
 SM 1238 Energy Meter 480 V AC   (6ES7238-5XA32-0XB0) 
 for voltage input (top)
 6ES7292-1AG40-0XA2 6ES7292-2AG40-0XA2 7-pin, tin-coated, coded in middle
 SM 1238 Energy Meter 480 V AC   (6ES7238-5XA32-0XB0) 
 for current input (bottom)  
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0 7-pin, tin-coated
 SM 1278 IO LINK
 (6ES7278-4BD32 0XB0)
 6ES7292-1AG30-0XA0 6ES7292-2AG30-0XA0 7-pin, tin-coated


Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.
Rate entry
no rating
Requests and feedback
What do you want to do?
Note: The feedback always relates to the current entry / product. Your message will be forwarded to our technical editors working in the Online Support. In a few days, you will receive a response if your feedback requires one. If we have no further questions, you will not hear from us.