Entry type: Product note Entry ID: 109780669, Entry date: 06/29/2020
(0)
Rate

Announcement Phase out: Expansion module switched Ethernet PROFINET 7KM9300-0AE01-0AA0

  • Entry
  • Associated product(s)
The expansion module Switched Ethernet PROFINET 7KM9300-0AE01-0AA0 will be replaced by the expansion module switched Ethernet PROFINET V3 7KM9300-0AE02-0AA0.

The expansion module Switched Ethernet PROFINET 7KM9300-0AE01-0AA0 was used for 7KM PAC3200, PAC4200 and for 3VA COM100/COM800.

The successor product, expansion module switched Ethernet PROFINET V3 7KM9300-0AE02-0AA0, supports the identical product and can be used for 7KMPAC3220 additionally.

Furthermore, it provides following PROFINET properties:
  • S2 system redundancy
  • configuration in Run
  • IRT Cycle time down to 500 µsec 
  • latest switching technology by Net load class III
The successor product is compatible with the phaseout product.


Target market

Target countries:
Germany, Austria, Bosnia-Herzegovina, Belgium, Belarus, Switzerland, Czech Republic, Denmark, Estonia, Spain, Finland, France, Great Britain, Greece, Croatia, Hungary, Ireland, Iceland, Italy, Kazakhstan, Lithuania, Luxembourg, Latvia, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Russia, Sweden, Slovenia, Slovak Republic, Turkey, Ukraine, Canada, USA, Mexico, El Salvador, Costa Rica, Guatemala, Nicaragua, Honduras, Panama, Argentina, Chile, Brazil, Colombia, Venezuela, Ecuador, Peru, Uruguay, Paraguay, Bolivia, Egypt, Algeria, Australia, Bangladesh, Burkina Faso, China, Côte d'Ivoire, Ghana, Hong Kong, India, Indonesia, Iraq, Iran, Israel, Japan, Jordan, Qatar, Kenya, Kuwait, Lebanon, Libya, Malaysia, Morocco, Mauritania, New Zealand, Nigeria, Pakistan, Philippines, Saudi
Arabia, Singapore, South Africa, South Korea, Syria, Taiwan, Thailand, Tunisia, United Arab Emirates, Vietnam
 

Target industry:
The module is primarily of interest to the manufacturing industry. However, PROFINET is also increasingly used in process automation and wind energy generation. The Ethernet switch functionality is interesting for all industries.

For an exchange from the phaseout product to the successor product, the TIA hardware configuration must be changed or the new GSDML applied.


Please refer to the following link for the successor product

https://support.industry.siemens.com/cs/ww/en/ps/7KM9300-0AE02-0AA0/pm