Notes on importing/exporting messages in ProTool V6.0

  • Entry
  • Associated product(s)

QUESTION:
Where can I find the functions "Edit > Import" and "Edit > Export" of ProTool V5.x in ProTool V6.0?

ANSWER:
These functions are not actively available in ProTool V6.0.

In the file "Protool.ini" ("Drive:\Siemens\ ProTool") please change the following entry in [Settings] from

OldMessageImportExport = 0

to

OldMessageImportExport = 1

After you restart ProTool, you will find the menu items "Import" and "Export" in "Edit".

Note:
Starting with ProTool V6.0 SP2, the functions Import/Export are activated again.

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit