Entry type: FAQ Entry ID: 15390241, Entry date: 11/14/2003
(0)
Rate

MMC102/103, new ONTRACK for high capacity harddisk.

  • Entry
  • Associated product(s)

QUESTION:
High capacity harddisks ( > 10GB) are unknown.
Following known problem:

MMC change (MMC102 -> MMC103) and the installed MMC software is < 03.06.xx (from 03.07.xx o.k. pre install on MMC103).

The 32 Bit access on MMC103 is blocked.

ANSWER:
Reason:
ONTRACK driverer 386 not loaded.

Solution:
The driver must be loaded in the following directory
C:\windows\ontrackw.386
the driver handle the function harddisk bigger 500 MB.

Copy ONTRACKW.386 to c:\windows and in SYSTEM.INI, replace the entry "device=*wdctrl" by "device=ontrackw.386".

Please check all SYSTEM.ini

C:\tools\SIEMENS.ORG\system.ini
C:\tools\USER.AKT\system.ini
C:\tools\USER.SAV\system.ini
C:\tools\WINDOWS.AKT\system.ini
C:\tools\WINDOWS.ORG\system.ini

C:\windows\system.ini

ONTRACKW.386.exe ( 143 KB )

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit