How do you create a hard copy printout if it cannot be printed directly?

  • Entry
  • Associated product(s)

Instructions:
If the hard copy cannot be printed directly, the hard copy can also be printed via a report.
 

No. Procedure
1 Create a new layout in the Report Designer.

To do this open the Report Designer in the WinCC Explorer and double-click on "Layout".

2 Insert the "Hard copy" object from the range of "Dynamic objects" into your layout.


Fig. 01
)
 
3 Insert the area selection in the properties for the hard copy object in the "Connect" tab.


Fig. 02
 
 
4 If you wish to print the full screen, select "Hardcopy of the entire screen (0)".


Fig. 03
 
 
5 Save your layout.
6 Create a new print job under "Report Designer > Print jobs" or use one of the print jobs specified there.
7 Open this print job and select the layout which you have created.


Fig. 04
 
 
8 You can now also use the print job which you have created to print a hard copy.
In order to execute the print job, insert the following C function into your C script or attach it to a button.

RPTJobPrint("print job name");

Keywords:
Print screen
 


Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.
Rate entry
no rating
Requests and feedback
What do you want to do?
Note: The feedback always relates to the current entry / product. Your message will be forwarded to our technical editors working in the Online Support. In a few days, you will receive a response if your feedback requires one. If we have no further questions, you will not hear from us.