Siemens Industry Online Support
Siemens AG
Entry type: FAQ Entry ID: 42486370, Entry date: 11/09/2010
(0)
Rate

SIMODRIVE 611U: Error 37

  • Entry
  • Associated product(s)
QUESTION:
This concerns the control card Firmware Versions Version V6.x (or later).
Error 037 - Error upon initializing user data. Additional information: 900 000hex
How can this error be corrected?

ANSWER:
Reformat FEPROM
Prerequisite: SimoComU >= V12.01

1. Establish online connection
2. Save parameter set: File>Store as file
3. Tools>Service>Format FEPROM
(A1106=Formatting completed)
4. Load the stored parameter set: File>Load into drive>Load and save in drive (the parameter set is stored in the FEPROM)

The fault has now been eliminated.

See also ID: 34797851
Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.