AP05: SINAMICS S120 Insulation monitoring on cranes

  • Entry
  • Associated product(s)

Task & solution

This application describes the situation when operating an IT system, that “first fault” changes an unearthed system (IT-system) into an earthed system (TN or TT system) and that a further fault may lead to the tripping of circuit breakers and hence lead to disconnection. One fault must be monitored and give a warning and controlled switching off of the equipment. We recommend a Bender Insulation Monitoring Device. And in this document we also described the settings from this device.

Download
  AP05_2018_05_BENDER.pdf (930,6 KB) 

Last Changes
05/2018, revised edition

 

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit