×
Siemens Industry Online Support
Siemens AG
文档类型 应用与工具 文档编号 56731718, 文档发布日期 2017年2月6日
(12)
评估

Integrated Engineering on the basis of COMOS with SIMATIC PCS 7 and SIMIT Simulation (Video)

  • 文档
  • 涉及产品
To meet the rising global competition in industry, it becomes more and more important to coordinate work processes efficiently due to the enormous cost and time pressure whilst reducing costs and saving resources at the same time.

The objective is the "digital plant". Integrated Engineering with COMOS, SIMATIC PCS 7 and SIMIT Simulation is a big step towards this goal. With these solutions, Siemens offers continuous engineering with central data management for plant designers and operators.

Joining these engineering tools guarantees an integrated plant management over the entire life cycle of an industrial plant.
Therefore, it is possible to shorten the "time to market", save costs, and increase the quality.

Video
The video "Integrated engineering with SIMIT, COMOS and SIMATIC PCS 7" shows the workflow between the single systems and gives you an overview about all necessary working steps.




Multimedia Demonstration
This multimedia demonstration gives you an opportunity to experience the concept of "Integrated Engineering" with COMOS, SIMIT Simulation and SIMATIC PCS 7 within a short time and in a comfortable way.

 

 Registrierung notwendig  Media system online view (2,5 GB)

Content
The multimedia demonstration contains general and technical videos about the topic of Integrated Engineering on the basis of COMOS with SIMATIC PCS 7 and SIMIT Simulation.

  • Integrated Engineering in the Process Industries
    General description for Integrated Engineering with COMOS and SIMIATIC PCS 7 for various sectors of the process industry.
  • Lifecycle Model
    Vision of the "digital plant".
  • Process Engineering
    Creating of block and intelligent process flow diagrams, as well as piping and instrumentation diagrams.
  • Electrical & Instrumentation Engineering
    Basic and detailed electrical engineering for plant and equipment.
  • Automation Engineering
    Creating functional designs of Control Modules (CM), Equipment Module Types (EMT), Equipment Modules (EM) and the easy processing of signals in logical diagrams.
  • Integrated DCS Data Synchronisation
    Functional description of the procedure for data exchange between COMOS and SIMATIC PCS 7.
  • Maintenance Management
    Functional description of the procedure for maintenance mangagement with COMOS Operations.
  • Virtual Commissioning with SIMIT Simulation
    Functional description of the procedure for data exchange between COMOS and SIMIT Simulation (customized solution).
  • Simulation Design with SIMIT Simulation
    Functional description of the procedure for the virtual commissioning of automation projects with SIMIT Simulation.

Further Information
COMOS Topic Page
 
Application Example - Controlled plant engineering from the outset with COMOS FEED
Application Example - Fast and easy generation of Piping and Instrumentation Diagrams with COMOS P&ID using a practical example
Application Example - Integrated Engineering with COMOS and SIMATIC PCS 7 using a practical example
Application Example - Simulation with SIMIT and SIMATIC PCS 7 using a practical example

Media System - SIMIT Simulation (Video)

Last changes
New video "Integrated Engineering on the basis of COMOS with SIMATIC PCS 7 and SIMIT Simulation"

Additional Keywords
E-Learning, Tutorial, Teaser, Webcast, Multimedia-based demonstration system, MMVS, Film, Screencast, Asset Information Management, Multimedia Demonstration