Siemens Industry Online Support
Siemens AG
Тип сообщения: Сообщение о продукте ID сообщения: 6233434, Дата сообщения: 19.01.2001
(0)
Оценить

810D: Release for general availability, CCU system software 3.3 version 03.03.18

  • Сообщение
  • Относится к продукту(ам)



The improved CCU system software 3.3, version 03.03.18 for SINUMERIK 810D/DE has been released for general availability and can be supplied.
This version replaces the supply version 03.03.08 on PC card and version 03.03.13 through E-Support.





1. Components which have been released, SW 3.3 version 03.03.18
6FC5450-3AY01-3AH3 SINUMERIK 810D



SYSTEM SOFTWARE CCU1

ON PC CARD (EXPORT)

UPDATE SW RELEASE 3.3

 

6FC5450-3AX02-3AH3 SINUMERIK 810D



SYSTEM SOFTWARE CCU2

ON PC CARD (STANDARD)

UPDATE SW RELEASE 3.3

2. Improved functionality

The customer-related improvements have been communicated to our customers.

3. Compatibility

CCU1 / CCU2

SW

2.4

3.1

3.2

3.3

3.3.18

MMC100.2 SW 4.4

SW 5.1

SW 5.2

SW 5.3

X

*

*

*

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

MMC 103 SW 4.4.17

SW 4.4.21

SW 5.1

SW 5.2

SW 5.3

X

X

*

*

*

 

X

X

X

X

 

X

X

X

X

 

X

X

X

X

 

X

X

X

X

MMC 103/OEM SW 4.4.17

SW 4.4.21

SW 5.1

SW 5.2

SW 5.3

X

X

*

*

*

 

X

X

X

X

 

X

X

X

X

 

X

X

X

X

 

X

X

X

X

HMI Advanced SW 6.0

X

X

X

X

X

OP 030 SW 3.6/3.7

SW 3.8

SW 4.1

SW 4.2

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

HPU SW 4.5

SW 5.1

X

X

X

X

X

X

X

X

X

X

HT6 SW 6.1

*1)

X2)

X2)

Start-up Tool SW 4.3

SW 5.1

SW 5.2

SW 5.3

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

PLC basic program SW 4.4

SW 5.1

SW 5.3

X

 

X

 

X

 

X

 

X

X



Explanation of characters:

X Compatible
* Essentially compatible, but not tested in detail
(blank) Not compatible
1) FC26 electronically available for SW 4.4
2) FC26 included in the toolbox from 05.03.04

 

4. Upgrade instructions

The upgrade instructions for CCU1 and CCU2 are available as readme file
in the "Diskette 2" ["Floppy disk 2"] directory in the

Toolbox SINUMERIK810D/840D

6FC5252-5AX21-3AG0 or
6FC5252-5AX21-3AG3
Version 05.03.05
under the file names

update_d.doc in German or
update_e.doc in English.

Comment: Version 05.03.04 of the toolbox refers to the CCU software version 03.03.08.
The start-up/upgrade algorithms, described there, are valid for all CCU versions 05.03.xx.

Link to INSTALLATION AND UPGRADE INSTRUCTIONS: 7579393


5. Function restrictions with respect to Catalog NC 60 /Edition 2000/2001:

- The "Synchronous spindle / polygon turning" function

6FC5255-0AB01-0AA1

   is based on a setpoint coupling and not on an actual value coupling.

- The "Gantry" function in combination with "Modulo rotary axes" is not possible.

- The number of gantry groups is restricted to one.

 



Указания по безопасности
Для обеспечения и дальнейшего поддержания кибер-безопасности технической инфраструктуры, систем, машин и сетей необходимо внедрить комплексную концепцию информационной безопасности, которая соответствует последним достижениям науки и техники. Продукты и решения Сименс являются всего лишь одним из компонентов такой концепции. Более подробную информацию о кибер-безопасности можно получить здесь
https://www.siemens.com/cybersecurity#Ouraspiration.
Оценить сообщение
без оценки
Вопросы и обратная связь
Что вы хотите сделать?
Примечание: отзыв всегда относится к текущей статье / текущему продукту. Ваше сообщение будет перенаправлено техническим редакторам службы онлайн-поддержки. В течение нескольких дней вы получите ответ, если ваш отзыв содержит вопрос. Если у нас не возникнут вопросы по вашему отзыву, мы не будем вас беспокоить.
Поддержка статистики
Данная функция позволяет выдавать идентификаторы (ID) результата поиска согласно желаемому количеству (формат .txt)

Генерировать список
Копировать URL
Отобразить эту страницу в новом дизайне
Панель управления mySupport