Siemens Industry Online Support
Siemens AG
Entry type: Product note Entry ID: 9837243, Entry date: 01/24/2002
(0)
Rate

840D: Release for general availability NCU system SW 6.3 Version 06.03.15 and Toolbox SW 6.3 Version 06.03.02  

  • Entry
  • Associated product(s)




Update with supplement from 09.01.2002; refer to text

1. Components which have been released, SW 6.3

 

Order No.[MLFB]

Designation

for NCU

NCU system software Version 06.03.15

6FC5250-6PX10-3AH_

NCU system software for 2 axes

561.2

6FC5250-6BX10-3AH_

NCU system software for 6 axes

571.2/571.3

6FC5250-6AX30-3AH_

NCU system software for 31 axes,
standard

572.3/572.4/
573.3/573.4

6FC5250-6BX30-3AH_

NCU system software for 12 axes,
standard

572.3/572.4/
573.3/573.4

6FC5250-6AY30-3AH_

NCU system software for 31 axes,
export

572.3/572.4/
573.3/573.4

6FC5250-6BY30-3AH_

NCU system software for 12 axes,
export

572.3/572.4/
573.3/573.4

Toolbox Version 06.03.02

6FC5252-6AX21-3AG_

810D/840D-Toolbox SW release 6.3

NCUs and CCUs


Last position of the Order No.[MLFB]:
                                      _  = 0 :  Single license
                                      _  = 3 :  Update

Software update contracts will be supplied with the update 6.3.

The orders with "actual software release" will be executed, when the order is entered, with "single license" SW 6.3.

Technology-PC cards are being prepared.



2. New functions
 

-

SIMODRIVE 611D with Performance 2 control:
Supplement 09.01.2002: This is valid for NCU system SW 12/31 axes.
The integrated drive release V06.03.09 allows drive modules with Performance 2 control to be connected. Drive functions and their values, refer to the upgrade instructions Point 4.40. 
Restriction: 
Mixed operation with Standard 2 or Performance 1 controls is not permitted.

-

PLC 314-2C-DP:
The NCU system software, from version 06.03.15 also allows the operation of NCUs  with integrated PLC 314-2C-DP (NCU 573.4; NCU 572.4 being prepared).
Comment: Toolbox 06.03.02 is required!

-

Additional improved functionality: Also refer to the Commissioning (start-up) and Upgrade Instructions, Points 4.1 to 4.39 !

NCU_060315_76.pdf ( 162 KB )

(Detailed description: Refer to the documentation for Package 6)



3. Compatibility                      (excerpt for NCU SW 4.4, 5.3 and 6.3)
 

 

NCU  

561.2

571.2/
573.2/573.3

572.3

573.4

 

SW release

4.4

5.3

6.3

4.4

5.3 

6.3

>=
4.4.38

>=
5.3.18

6.3

6.3

MMC100.2

4.4
5.1
5.2
5.3

X
*
*
*

X
X
X
X

X
X
X
X

X
*
*
*

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

HMI Embedded

6.1
6.2

 

X

X

 

X

X

 

X

X

X

OP 030

3.6/3.7
3.8
4.1
4.2

*
*
*
*

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

PHG

4.5
5.1

*
*

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

HT 6

6.1

*1)

X2)

X2)

*1)

X2)

X2)

X2)

X2)

X2)

X2)

MMC 103
and
MMC 103/OEM

4.4.17
ab 4.4.21
5.1
5.2
5.3

X
X
*
*
*


X
X
X
X


X
X
X
X

X
X
*
*
*


X
X
X
X


X
X
X
X

X
X
*
*
*


X
X
X
X


X
X
X
X


X
X
X
X

Start-up tool

4.3
5.1
5.2
5.3

*
*
*
*

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

HMI Advanced

6.0
6.1
6.2

X
X

X
X
X

X
X
X

X
X

X
X
X

X
X
X

X
X

X
X
X

X
X
X

X
X
X

Basic PLC program

4.4
5.1
5.3
6.1
6.3

X



X
X




X
X

X



X
X




X
X

X



X
X




X
X





X

 

Explanation of characters:

X

Compatible

 

*

Essentially compatible but not tested in detail

 

(empty)

Not compatible

 

1)

FC26 for SW4.4 is electronically available

 

2)

FC26 in is included in the Toolbox from 05.03.04



4. System inter-dependencies with software release 6.3
 

The numerous new and expanded functions in SW release 6 take-up more memory space/performance and mean, from SW release 6.3, the following system inter-dependencies:

-

NCU 571.2: NCU system SW 6 axes has been released for 1 channel and 6 axes
(an innovated hardware NCU 571.3 is being prepared; here again, 2 channels and axes will be available)

-

NCU 572.3: NCU system SW 31 axes has been released with up to 6 channels and 31 axes

-

NCU 573.3:  NCU system SW 31 axes has been released with up to 8 channels and 31 axes

Additional system inter-dependencies/secondary conditions: Refer to the Commissioning (Start-up) and Upgrade Instructions.





Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration.
Rate entry
no rating
Requests and feedback
What do you want to do?
Note: The feedback always relates to the current entry / product. Your message will be forwarded to our technical editors working in the Online Support. In a few days, you will receive a response if your feedback requires one. If we have no further questions, you will not hear from us.