Siemens Industry Online Support
Siemens AG
Filter criteria for entries
All Products My Products
Product tree
 
 
Clear all filters
Product
Search product
Entry type
 
Date
Thumbnail

6ES5466-8MC11
466-8 ANALOG INPUT, 4AI, 0-10V, FLOAT.
***Spare part*** SIMATIC S5, Analog input 466 for S5-90U/-95U/-100U, ET 100U, ET 200U 4 inputs 0 to 10V

  • Save filter
  • Load filter
  • email on update
250
Entries
Filtered by
'
6ES5466-8MC11
'
 
Entries per page: 20 50 100
...
1
2
3
4
5
...
Certificate General Product Approval, UL, UL

UL: NRAQ.E116536 USA, Link: Online Certification Directory, Programmable Controllers ( Steuerungen, Dez. Peripherie, Basic Panels 1st/2nd Gen., Key/Comfort/Micro/Mobile Panels.. ) UL-File: NRAQ.E116536 USA

09/01/2017
ID: 102378296
(1)
FAQ Which backup batteries can you use in a SIMATIC S5?

Backup batteries for SIMATIC S5

08/28/2015
ID: 7379933
(4)
FAQ Durability and storage life of batteries

QUESTION:   What is the storage life of the back-up battery? ANSWER:...

04/21/2008
ID: 10181929
(0)
FAQ S5-95U Conditions of Replacing Block MB0x with MD0x

QUESTION: Can I replace my S5-95U (MLFB: 6ES5 095-8MB02) with a 6ES5 095-8MD03? ...

08/23/2004
ID: 17053021
(0)
FAQ Amendment to Manual "Second serial Interface of S5-95U" Break Detection

QUESTION:   How does the S5-95U with two interfaces (order no.: 6ES5095-8MC..) a BREAK on the second interface? ...

08/17/2004
ID: 19350101
(0)
FAQ S5-95F: generating EPROM signature offline

QUESTION: Can I generate the EPROM signature for the S5-95F also offline? ANSWER:...

07/27/2004
ID: 188431
(0)
FAQ Battery Monitoring of S5-90U

QUESTION:   What has to be observed for S5-90U regarding back-up battery? ANSWER:  ...

07/19/2004
ID: 19211581
(0)
FAQ Digital input/output module 6ES5 482-8MA13 (16DE/16DA) and on-board I/O of the AG 95 / pulse at the digital outputs

QUESTION: When the power supply L+ (24V) is switched to the module, the outputs switch through for a short time. How can I suppress this pulse? ...

06/24/2004
ID: 153554
(0)
FAQ S5-95U: saving input information of the onboard I/O in the case of mains failure

QUESTION:   How can the input information of the onboard I/O be saved securely in the case of power failure so that it is available again when the power returns? ...

06/03/2004
ID: 19039743
(0)
FAQ Usage of Diagnostics Repeaters and STEP 5

QUESTION:   How can I use the diagnostics functions of the diagnostics repeaters with STEP 5? ...

05/10/2004
ID: 18650944
(0)
FAQ Notification of correction to the manual "S5-95U - Setting Parameters in DB1 for enabling the integrated clock"

QUESTION:   How do I proceed to change the parameters in DB1 for enabling the integrated clock? ...

03/22/2004
ID: 18689142
(0)
FAQ STEP 5 V7.1 on PGs with COM Packages

QUESTION: Why does the error message 'insufficient memory' appear when starting COM packages on PG with STEP 5 V7.1? ...

03/08/2004
ID: 1004543
(0)
FAQ Safety of electronic controllers ET200 - wire breakage can lead to the setting of outputs.

QUESTION: How is it possible that an assembly fault with a single or multiple wire breakage in the connection cable (I/O bus) between the ET200 bus modules leads to outputs of the DA 451 being set? ...

11/12/2003
ID: 17566821
(0)
FAQ PROFIBUS connection of the S5 100 U via CP541 is possible

QUESTION: Is there a possibility of connecting the S5 100 U with the PROFIBUS? ...

09/23/2003
ID: 17090003
(0)
FAQ Memory concept of the AG 95

QUESTION: How large is the memory of the AG 95 and how can I use it? ANSWER:...

08/29/2003
ID: 142591
(0)
FAQ Configuration of an ET200U digital input component using a CP5431 FMS

QUESTION:   How can I connect an ET200U to an S5 135 U over a CP5431, when a digital input component (6ES5422-8MA11) is used in the ET200U? ...

08/25/2003
ID: 16805657
(0)
FAQ Which Details does Technical Support need regarding Inquiries on signal preprocessing modules and technological functions of SIMATIC S5

QUESTION: Which Details does Technical Support need regarding Inquiries on signal preprocessing modules and technological functions of SIMATIC S5? ...

08/15/2003
ID: 16650198
(0)
FAQ Description of the AG95U DP master

QUESTION: Where is the AG95 DP master described? ANSWER:...

08/08/2003
ID: 37417
(0)
FAQ Special SINEC L2-DP-Data (AG95-DP Master)

QUESTION: What are the specific SINEC L2-DP-Data (Number of DP slaves ...)? ANSWER:...

07/09/2003
ID: 37390
(0)
FAQ Onboard analog inputs of AG 95U – possible loss of accuracy when used as digital inputs

QUESTION:   Can the analog inputs of the AG 95U also be used as digital inputs? ...

06/03/2003
ID: 1020635
(0)
 
Entries per page: 20 50 100
...
1
2
3
4
5
...