6SL3125-1UE32-2AA0
SINAMICS S120 HIGH FREQUENCY 225A, 16KHZ
SINAMICS S120 HIGH FREQUENCY DRIVE MOTOR MODULE 225A, 16 KHZ INPUT: DC 600V OUTPUT: 3AC 400V, 225A MAX: OUTPUT FREQUENCY 1200 HZ FRAME SIZE: BOOKSIZE

  • Save filter
  • Load filter
  • email on update
34
Entries
Filtered by
'
6SL3125-1UE32-2AA0
'
 
Entries per page: 20 50 100
...
1
2
...
Product note SINAMICS technical documentation

Irrespective of the particular application, whether you require online help for a specific machine message when operating a product, you wish to take the time and get to know a product or you wish to compile documentation for your own individual purposes: With us, you can find the current editions of technical documentation electronically, on data carrier and printed out.

04/26/2018
ID: 108993276
(17)
Certificate Functional Safety/Safety of Machinery, Manufacturer Declaration, Manufacturer

Safety Manufacturers Declaration 668.DCOBG0318.40.032

04/11/2018
ID: 66209228
(1)
Certificate Declaration of Conformity, EC/EU-Declaration of Conformity, Manufacturer

EC-Declaration of Conformity 664.MENRo.BG.02.1710.008

11/24/2017
ID: 60438382
(0)
Application example Torque Calibration with DCB Extension

In order to achieve a high torque precision, e.g. for test stand processes, it is necessary to calibrate the drive system. Using the application example, users can precisely generate the torque setpoint at to the motor shaft. After successful calibration, the torque actual value at the shaft can be calculated without requiring an installed measuring shaft.

11/16/2017
ID: 109747858
(7)
Certificate Declaration of Conformity, C-TICK, Manufacturer

C-TICK Declaration 668.DCOBG1017.40.011

10/18/2017
ID: 76783108
(0)
Application example SINAMICS S120 DCC-Application: Using Booksize Motor Modules as braking chopper

The application provides a solution for connecting a braking unit to the DC link. When a DC link voltage threshold is exceeded, this automatically dissipates the excess energy to protect the components against overvoltage.

09/05/2017
ID: 104148244
(0)
Certificate Functional Safety/Safety of Machinery, SIL-Declaration of conformity

IFA 1001262 1001262_16-12-05

03/01/2017
ID: 29279648
(0)
Certificate Test Certificates, Declaration of the Compliance with the order, Manufacturer

Test Certificates, Declaration of the Compliance with the order 2.1, Manufacturer, Ex t, converter operation (Micromaster, ET200S-FC, Simovert Masterdrives VC, SINAMICS G110) A5E38572797A

07/21/2016
ID: 109739354
(0)
Certificate Test Certificates, Declaration of the Compliance with the order, Manufacturer

Test Certificates, Declaration of the Compliance with the order 2.1, Manufacturer, Ex n, converter operation (Micromaster, ET200S-FC, Simovert Masterdrives VC, SINAMICS G110) A5E38402476A

07/21/2016
ID: 109739357
(0)
Certificate China-RoHS, Manufacturer

Statement to China-RoHS directive for Low-voltage products

06/30/2016
ID: 109738665
(0)
FAQ Switching a S120 Motor Module to a loaded DC-Link

At the moment there is the demand for a selective switching of individual Motor Modules during operation on a site. As an example to switch off a defective Motor Module connected to a loaded DC-Link or to switch on a repaired Motor Module to a loaded DC-Link

06/15/2016
ID: 109738394
(8)
FAQ SINAMICS S120: Message A30042 "Fan has reached its maximum operating hours"

The service life of a fan can deviate from the factory setting of = 40.000h. In order to ensure that the inverter remains ready for operation, the fan should be replaced – and the operating hours counter reset (p0251, p0254).

11/09/2015
ID: 109480518
(5)
Product note Technical Online-Documentation for SINUMERIK, SINAMICS, SIMOTION and SIMOTICS

The technical documentation for the four product families is provided online in the Siemens Industry Online Support.

10/14/2015
ID: 109476679
(126)
Manual SINAMICS S120 High Frequency Drive

(SH2), 04/2015, System manual, 6SL3097-4AH10-0BP3

09/16/2015
ID: 109479610
(3)
Product note DOConCD V4.5 SP4 technical documentation for SINUMERIK in German and English

A new edition of the documentation collection DOConCD for SINUMERIK controllers 840D sl and 828D is available with immediate effect. Article number: 6FC5398-0AC10-1YA2 Delivery location: LZE

08/26/2015
ID: 109479135
(6)
FAQ Spare parts, repair services for SINUMERIK, SINAMICS

SINUMERIK, SINAMICS, SIMODIRVE, SIMOVERT, MASTERDRIVES, MICROMASTER, COMBIMASTER, POSMO, SIMOTION, SIMOTICS

04/24/2015
ID: 75851794
(2)
Product note Documentation set SINAMICS Manual Collection – 06/2014

Effective immediately, there is an updated DVD-ROM available with documentation in the languages English, German, French, Italian, Spanish and Chinese. ...

12/04/2014
ID: 106263621
(0)
FAQ SINAMICS S120: Temperature sensors for SINAMICS components

Summary: More detailed information can be found in the SINAMICS S120 Commissioning Manual, 04/2014, in Chapter 3.19 Temperature sensors for SINAMICS components. ...

12/03/2014
ID: 104980446
(1)
FAQ SINAMICS S120: Direction of rotation reversal of a servomotor

Summary Parameter p1821 can be used to change the direction of rotation of the motor. ...

07/03/2014
ID: 96838164
(3)
FAQ Sinamics S120: Package contents of 6SL3162-0A... replacement fans

Summary A replacement fan article number 6SL3162-0A... always includes a complete fan set. ...