FAQ How do you connect the SM 1281 to the MindSphere?

With FW3.1 MS the SM 1281 has the option of connecting directly to the MindSphere.

For products: 6AT8007-1AA10-0AA0, 6AT8007-1AA20-0AA0
05/23/2019
ID: 109762834
(4)
FAQ How do you diagnose a rolling bearing with the SM 1281 taking into account the bearing data and fault frequencies?

The SM 1281 can analyze the bearing components of a rolling bearing in such a way that you can obtain information about how urgent it might be to make replacements. For this the SM 1281 needs bearing-related data as described in this entry.

For products: 6AT8007-1AA10-0AA0
11/21/2018
ID: 109761652
(3)
FAQ What is the meaning of the error message "Invalid/inconsistent firmware present" when configuring a SIPLUS SM 1281?

The error message is displayed if you have loaded only the hardware configuration into the CPU but not yet any program or you are using the wrong version of the LSM1281 block library.

10/12/2017
ID: 109749077
(0)
FAQ How can trends and raw data recorded by SIPLUS CMS1200 SM 1281 be visualized in X-Tools?

Valid measured variables are automatically stored as trends within the SM 1281. It also stores raw data of recorded vibration signals to WAV files.

For products: 6AT8000-0AB00-2BA0, 6AT8007-1AA10-0AA0
12/22/2016
ID: 109741669
(1)
FAQ How do you configure SIPLUS CMS1200 or CMS2000 to monitor a machine at rotation speeds below 120 rpm?

In practice, it often occurs that a monitored machine unit is operated at a rotation speed below 120 rpm. SIPLUS CMS1200 and CMS2000 only start monitoring at a rotation speed of 120 rpm. Below that, configured values are calculated but not compared to limits.

09/27/2016
ID: 109740911
(0)
FAQ How can raw data recorded with SIPLUS CMS1200 SM 1281 be transferred from the device to a PC?

The SIPLUS CMS1200 SM 1281 condition monitoring system facilitates the recording and internal saving of raw data in the form of WAV files. The term raw data refers to direct records pertaining to all activated vibration channels and additional the speed channel.

09/27/2016
ID: 109741051
(0)
FAQ How do you configure the monitoring of double bearings with different bearing types in a SIPLUS CMS1200 or SIPLUS CMS2000?

In practice it may happen that mechanically caused (force) a shaft needs a double bearing. In this case the bearings are often different (type and manufacturer). This FAQ shows how an active monitoring of both bearings is possible with only one sensor.

09/14/2016
ID: 109736550
(0)
FAQ Which sensors are applicable for SIPLUS CMS1200 SM 1281 and SIPLUS CMS2000 and how are they installed electrically and mechanically?

To get measurement data for SIPLUS CMS1200 SM 1281 or SIPLUS CMS2000, vibration feeders are necessary. To get clearly analyzable signals, the right sensors have to be selected and they must be correctly mounted and connected.

09/13/2016
ID: 109740202
(2)
FAQ Why is the ION SIMATIC S7-300 T001 version V 03.01 attached to X-Tools with version V 03.00?

QUESTION:   Why is the ION SIMATIC S7-300 T001 version V 03.01 attached to X-Tools with version V 03.00? ...

For products: 6AT8000-0CA00-0XA0
02/12/2014
ID: 88579135
(0)
FAQ How can recorded trends from SIPLUS CMS2000 be displayed in X-Tools?

QUESTION:   How can recorded trends from SIPLUS CMS2000 be displayed in X-Tools? ...

For products: 6AT8002-1AA00
11/08/2013
ID: 83179857
(0)
FAQ How does the FTP access work for the SIPLUS CMS2000?

QUESTION:   How does the FTP access work for the SIPLUS CMS2000?  ...

09/11/2013
ID: 80580005
(0)
FAQ How can SIPLUS CMS2000 communicate via powerline?

QUESTION:   How can SIPLUS CMS2000 communicate via powerline?  ...

07/29/2013
ID: 78301931
(0)
FAQ How can recorded raw signals from SIPLUS CMS2000 be displayed in the form of spectra via X-Tools on the basis of fast analysis models?

QUESTION:   How can recorded raw signals from SIPLUS CMS2000 be displayed in the form of spectra via X-Tools on the basis of fast analysis models? ...

05/27/2013
ID: 66276211
(0)
FAQ How can recorded raw signals from SIPLUS CMS2000 be displayed in the form of spectra via X-Tools?

QUESTION:   How can recorded raw signals from SIPLUS CMS2000 be displayed in the form of spectra via X-Tools? ...

05/08/2013
ID: 66276470
(0)
FAQ Where can I find data sheets concerning SIPLUS CMS2000?

QUESTION:   Where can I find data sheets concerning SIPLUS CMS2000?  ...

05/07/2013
ID: 68813090
(0)
FAQ Where can I find data sheets concerning SIPLUS CMS4000?

QUESTION:   Where can I find data sheets concerning SIPLUS CMS4000?  ...

05/07/2013
ID: 68853032
(0)
FAQ How should the acceleration sensor be mounted on the bearing?

QUESTION:   How should the acceleration sensor be mounted on the bearing?  ...

For products: 6AT8002-1AA00, 6AT8002-4AB00, 6AT8002-2AA00
03/21/2013
ID: 68213352
(0)
FAQ Where can I find further information about SIPLUS CMS2000 VIB-SENSOR S01?

FRAGE:   Where can I find further information about SIPLUS CMS2000 VIB-SENSOR S01? ...

For products: 6AT8002-4AB00, 6AT8002-4AC10, 6AT8002-4AC03
03/18/2013
ID: 68583660
(0)
FAQ How can the firmware of IFN VIB-ACC and IFN AI be updated via SIPLUS CMS X-Tools?

QUESTION:   How can the firmware of IFN VIB-ACC and IFN AI be updated via SIPLUS CMS X-Tools? ...

03/08/2013
ID: 67412649
(0)
FAQ Hotfix for the use of Output Functions within Analyzing Scripts in SIPLUS CMS X-Tools V 03.05

QUESTION:   With the use of Analyzing Scripts in X-Tools V 03.05, in limited cases Output Functions can lead to a crash. How can this be fixed? ...

12/04/2012
ID: 66579262
(0)
 