×
Siemens Industry Online Support
Siemens AG
Filter criteria for entries
All Products
My Products
Product tree
 
 
Clear all filters
Product
Search product
Entry type
 
Date
  • Save filter
  • Load filter
  • email on update
245
Entries
Filtered by
'
3VT Molded Case Circuit Breakers up to 1600 A
'
and
'
Technical data
'
 
Entries per page: 20 50 100
...
1
2
3
4
5
...
Compare technical data
Technical data CIRCUIT BREAKER VT 1000 H

circuit breaker 3VT4 high breaking capacity Icu=65kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch

3VT4710-3AA30-0AA0
06/12/2019
Technical data CIRCUIT BREAKER VT 1600 H

circuit breaker 3VT5 high breaking capacity Icu=55kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch

3VT5716-3AA30-0AA0
06/12/2019
Technical data CIRCUIT BREAKER VT 160 N

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. without auxiliary release without auxiliary/alarm switch

3VT1716-2DA36-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 160 N

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=25A rated current IR=20...25A overload protection II=250...375A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VT1792-2DC36-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 630 N

circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch

3VT3763-2AA46-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 630 H

circuit breaker 3VT3 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch

3VT3763-3AA46-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 160 N

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=16A rated current IR=12.5...16A overload prot. II=160...240A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals

3VT1701-2DC35-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 250 N

circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch

3VT2725-2AA36-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 630 N

circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch

3VT3763-2AA36-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 160 N

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=32A rated current IR=25...32A overload protection II=160...320A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VT1703-2DC36-0AA0
06/06/2019
Technical data CIRCUIT BREAKER VT 160 N

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VT1712-2DC36-0AA0
06/06/2019
 
Entries per page: 20 50 100
...
1
2
3
4
5
...
Support to the statistics
With this function the IDs found are listed according to number (format .txt).

Generate list
Copy URL
Display page in new design
mySupport Cockpit
Related links