Sorry to gravedig, but is this possible in VBS? Thanks ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 4/4/2018 12:57:13 PMNew subject after splitting |
|
4/5/2018 1:44 PM | |
Joined: 10/3/2010 Last visit: 9/15/2025 Posts: 1568 Rating:
|
Depending on your needs, you can create something similar with VBS. First create an internal tag of the type "Text tag 8-bit". You can manipulate the value of this internal tag by VBS to write another tagname in it. In your I/O-field, you can link the outputvalue-property to the internal tag and enable the "indirect" checkbox behind it. This way you can change the tag used in an I/O-field just by write another tagname to the internal text tag. |
B r g d s , |
|
1/13/2022 3:49 PM | |
Joined: 10/3/2010 Last visit: 9/15/2025 Posts: 1568 Rating:
|
hi vcamp7 did you check if my previous reply could work for your needs? |