1/16/2018 9:53 PM | |
Joined: 4/28/2015 Last visit: 5/9/2023 Posts: 10 Rating: (0) |
Hi Liai, Thank you. I tried your code and it worked with spindle override. What is variable that I can use to get axis feedrate? I'd like to do same thing to detect axis feedrate to prevent operator wrongly change axis feedrate override. Thank you.
------------------------------------------------------------------------------------------ |
Last edited by: AutoGen_1005268 at: 1/17/2018 1:40:14 AMLast edited by: Jen_Moderator at: 1/17/2018 8:15:47 AMNew subject after splitting. Division of questions into separate topics. |
|
1/18/2018 10:51 AM | |
Joined: 1/19/2008 Last visit: 8/13/2024 Posts: 989 Rating: (63) |
hi $AC_PLC_OVR Pee |
This contribution was helpful to1 thankful Users |
1/19/2018 9:45 PM | |
Posts: 26 Rating: (2) |
I believe you can use $AC_F for commanded/desired and $AC_VACTWF for actual. |
Follow us on