6/26/2019 9:17 AM | |
Posts: 16 Rating: (1) |
Hi all, I don see any entry about to write the parameters in the drives. I managed to write the values in the parameters 1120, 1221, ... but i cant change the motor parameters. I can not find the motor parameters via TIA Openness. This is the code that i used: DeviceItem item = MyProject.Devices[0].Items[0].Items[0]; DriveParameter parameter304 = drive.Parameters.Find("304[0]");
I tried too finding the parameter like this: DriveParameter parameter304 = drive.Parameters.Find("0304[0]"); DriveParameter parameter304 = drive.Parameters.Find(0304,0); Thanks ------------------------------------------------------------------------------------------ |
Last edited by: The Helping Hand at: 06/26/2019 14:32:15New subject after splitting Last edited by: Ekhi_elktr at: 07/01/2019 10:40:08 |
|
3/11/2020 1:45 PM | |
Joined: 8/15/2011 Last visit: 9/9/2024 Posts: 145 Rating: (13) |
hello, try this: https://support.industry.siemens.com/cs/ww/en/view/109763476 |
This contribution was helpful to2 thankful Users |
3/11/2020 3:17 PM | |
Joined: 8/15/2011 Last visit: 9/9/2024 Posts: 145 Rating: (13) |
hello, try "TIA Openness Explorer": https://support.industry.siemens.com/cs/ww/en/view/109760816 to check parameter and access level... |