10/19/2019 11:51 AM | |
Posts: 1 Rating: (0) |
Dears, Please i need urgent help as i faced the same problem twice in the same day in different cranes PSU2 (6SE7038-6GL84-1JA1) installed for long time and some component defected as shown without any action i need to know the reason pls. ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 10/21/2019 06:19:18New subject after splitting |
|
10/30/2019 12:35 PM | |
Posts: 61 Rating: (1) |
Hi, The picture is from a step down power supply of 15V, that's supply the T board where is the IGBT firing circuit. This problem can occur for a various reasons. One of them is a defective firing board, or a overcurrent due to a short circuit in the firing circuit, MTBF of the electronics componets, and others. Look at the T board and the IGBT first... Hope it helps.
|