11/27/2019 6:44 AM | |
Posts: 95 Rating: (0) |
sir, how to clear plc and nc data? guide me proper way to install nc and plc back up data. i have backup on ncu memory card.. |
11/27/2019 8:01 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Please refer attached file. For restoring please refer file NC_PLC back up page 4 point no 17. HTH. AttachmentNC-PLC_archive_clear_restore procedure.zip (733 Downloads) |
11/28/2019 6:58 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Please attach the snap shot of NCU seven segment display. HTH |
12/2/2019 8:40 AM | |
Posts: 95 Rating: (0) |
no sir, now another backup data download to nc and plc. now emergency stop 3000 and y1 and A axis hardware active encoder error shows. help me sir |
12/3/2019 9:52 AM | |
Posts: 95 Rating: (0) |
dear sir, here i had attached photo. after nc ,plc data clearing , i had had installed backup,but now this faults occur. |
12/3/2019 10:21 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Hello, How old is the NCU & PCU? From the attched screen shot, NCU battery life seems to be over. Please check the battery voltage by DMM, it should be 3.0 - 3.1 volt. If it is less than 2.9 volt, battery needs replacement. Do you have spare battery? If NCU unit is quite old, I suggest you to procure complete NCU fan unit along with battery & replace it. Please refer attached sheets for detailed information. After replacement of battery, you need to reload NC/PLC back up again. Regarding 120021 PCU fan monitoring alarm, open PCU rear cover & check if the PCU fan is free or its jam. (Ofcourse check this when power supply is completely OFF). If fan is Jam, you need to replace it. HTH. Attachment840D NCU battery replacement.pdf (347 Downloads) |
12/6/2019 7:05 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Did you got your machine problem solved? |
12/6/2019 9:48 AM | |
Posts: 95 Rating: (0) |
dear sir, battery already changed. voltage is 3.1v dc |
12/11/2019 11:58 AM | |
Posts: 95 Rating: (0) |
in other 840d nck fan alarm comes but machine works fine. there is no emergency alarm with nck fan. |
12/12/2019 10:16 AM | |
Posts: 95 Rating: (0) |
no values show sir, i am using alphabet "X" for db10.dbx104.6 there is no symbol for multiplier. |
12/12/2019 10:18 AM | |
Posts: 95 Rating: (0) |
before reset |
12/12/2019 10:19 AM | |
Posts: 95 Rating: (0) |
during reset pb pressed. |
12/13/2019 5:29 AM | |
Posts: 95 Rating: (0) |
dear sir, screenshot attached here. |
12/13/2019 6:06 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
OK. Please check DB10.DBX56.1 & DB10.DBX56.2 signal status & attach screen shot here. |
12/13/2019 7:38 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Do you have PLC ladder back up? Could you attach it here? |
12/13/2019 7:52 AM | |
Posts: 95 Rating: (0) |
screen shot attached. |
12/13/2019 7:55 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Got it. Please refer my previous post reply. |
12/14/2019 6:48 AM | |
Posts: 95 Rating: (0) |
axis 4 |
12/14/2019 6:53 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
If you have software, cable then connect & go on line as explained in my earlier post. |
12/14/2019 11:11 AM | |
Posts: 95 Rating: (0) |
dear sir, go online,found q43.7 is for servo ready. q43.7 is getting high from out5 of fc 204. screen shot attached. |
12/14/2019 11:12 AM | |
Posts: 95 Rating: (0) |
plc rung |
12/14/2019 11:13 AM | |
Posts: 95 Rating: (0) |
rung plc |
Last edited by: farukh sama at: 12/14/2019 12:11:16 |
|
12/14/2019 11:56 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Can you attach PLC project here? Save in PC, compress it in zip folder & attach here. |