Hello Experts: For the V90 servo controller , how to communicate and control it use simotion D? Thank you very much! |
| 4/23/2017 6:54 AM | |
|
Posts: 1529 Rating:
|
With V90PN, it is just like any other axis. With the standard PTO, you need an IM 174 module to do the pulses |
| 4/25/2017 7:14 AM | |
|
Posts: 1529 Rating:
|
Yes. From an axis standpoint, SIMOTION does not care what drive it connects to. However, since no DSC, position performance is limited compared to S120. |
| 7/12/2017 6:13 AM | |
|
Joined: 5/12/2006 Last visit: 12/19/2025 Posts: 22816 Rating:
|
Hello, the GSD can be downloaded here: https://support.industry.siemens.com/cs/ww/en/view/109737269 Use Standardtelegram 3 or Telegram 102.
Christoph |
| 7/17/2017 11:43 AM | |
|
Posts: 8171 Rating:
|
New question published by 心悦88 is split to a separate thread with the subject How control V90PN use S315-2PN/DN Profinet?. Best regards |