Hello, I have a problem with a CPU315 2DP. The next error message appears on diagnostic buffer and the cpu dont RUN. Regardless the configuration tested, these two event appears again and again... I am totally desapointed and desperate See attached file for more explanation. Event1 of 128: Event ID 16# 49A0 STOP caused by parameter assignment error or unpermissible difference between preset and actual configuration: startup disabled No relevance for user (SDB no.): 1 No relevance for user (Z2): 0250 (Z3): 8805 Previous operating mode: STARTUP (warm restart) Requested operating mode: STOP (internal) External error, Incoming event 02:46:29.974 PM 10/18/2012_____________________________________________________________ Event 20 of 128: Event ID 16# 5962 Parameter assignment error preventing startup in CPU module parameters Parameter: area Output address: 592 of the module with parameter assignment errors Error type: parameter not in permitted range Operating mode: STOP (internal) External error, Incoming event 02:46:24.415 PM 10/18/2012 (This is not output 592 in my config!!) AttachmentConfig.zip (431 Downloads) |
Last edited by: Raph_GY at: 10/22/2012 7:48 PM |
|
10/22/2012 10:24 PM | |
Joined: 9/27/2006 Last visit: 9/13/2024 Posts: 12282 Rating: (2683)
|
Hello Raph; |
This contribution was helpful to1 thankful Users |
1/19/2021 6:06 AM | |
Joined: 7/7/2018 Last visit: 7/21/2024 Posts: 11 Rating: (0) |
Hello sir, I have same issue but little different, we have Schneider drive slave and slave Remote profibus DP IO. We are facing some issue that Remote panel (Slave 8)getting stopped, it is the last device in the network. Before this we have Schneider drive (Slave 7). it was stopped and started. Now running but sometimes making this issues. we already changed profibus connector. In simatic manager we already installed OB82, OB86. Is there is any problem in cable? how i can rectify this issue.
|
9/14/2024 7:29 AM | |
Joined: 3/19/2019 Last visit: 9/14/2024 Posts: 102 Rating: (0) |
Hi dchartier, I am having the network issue with S7410E PLC with all the IM55-6 modules, I added diagnostics buffer here. I changed the update time for all the IM modules from automatic to 64ms. but still issue not solved. Kindly help us to solve this issue. Diagnostic buffer: Event 26 of 3200: Event ID 16# 72A5 PROFINET IO: return of redundancy at station Address of the affected station: Input address: 16351 IO system ID: 102 Station number: 4 Log. base address of the IO controller: 16363 Requested OB: I/O redundancy error OB (OB70) Priority class: 24 Outgoing event 10:40:50.878 AM 09/14/2024 (Coding: 16# 72A5 1846 C454 3FEB 3FDF 9004) Event 27 of 3200: Event ID 16# 38CC PROFINET IO: station return but disrupted/in maintenance Address of the station involved: Input address: 16339 IO system ID: 100 Station number: 7 Log. base address of the IO controller: 16383 Requested OB: Rack failure OB (OB86) Priority class: 25 External error, Outgoing event 10:40:48.992 AM 09/14/2024 (Coding: 16# 38CC 1956 C454 3FFF 3FD3 8007
AttachmentCPU Diagnostic Buffer 14092024.pdf (0 Downloads) |