Hi, it not possile to upload to PG when CPU was projected with an higher version of TIA as installed on you PC. Please check this: What options are available in STEP 7 (TIA Portal) for uploading when the project version in the CPU no longer matches the version on your PG/PC?Regards, Towome |
|
|
1/9/2019 12:58 PM | |
Joined: 3/5/2014 Last visit: 8/5/2022 Posts: 5521 Rating: (1051)
|
hi, When this PLC was projected with V14 you also need V14 to load it back into a project. You can have a look in Online&Diagnostics. There you can see which TIA-version was used for the project on this CPU. Step7 V14 inkl SP1 can be downloaded here: SIMATIC STEP 7 including PLCSIM V14 SP1 TRIAL download But this contains only a TRIAL-license-key, that is valid for 21 days. Existing V13-License-keys can be upgraded. Therefore you need to buy an upgrade-license. hope this helps, regards, |