7/15/2010 12:05 PM | |
Joined: 4/23/2010 Last visit: 11/14/2024 Posts: 8092 Rating: (878) |
Hello Melwyn, Please check this link, page no 10. http://ftp.gongkong.com/UploadFile/datum/2008-9/2008090913232000001.pdf For 1LG4 series at KT=40 Deg Cent Service factor SF=1.1 DEEP. |
This contribution was helpful to2 thankful Users |
7/15/2010 2:39 PM | |
Posts: 17 Rating: (0) |
Thnx DEEP, The local guys were not able to provide this detail & you helped me out. Regards, Mel |
6/27/2016 9:16 AM | |
Joined: 9/3/2014 Last visit: 3/13/2019 Posts: 4766 Rating: (122) |
New question published by Vial is split to a separate thread with the subject Maximum rotation for a motor. Model: 1LG4 228 6EA90 (225M) 37kW. Best regards |