6/16/2020 1:39 PM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Hello, You can access Sinamics drive data directly on OP without connecting external device i.e. field PG or PC. Press SHIFT + SYSTEM?ALARM keys on OP simulteneously, so system start screen (fig 7.1) will get displayed, press MACHINE DATA softkey, so machine data screen (fig 7.6) will get displayed, on this screen press DRIVE MD softkey, so SINAMICS DRIVE data will get displayed, to view particular axis data, place/select axis by placing or selecting particular axis all parameter values will be displayed. For more detail information, please download & refer below manuals. SINUMERIK 802D sl, Turning, Milling P. S. Please refer attached sheet for detail drive parameter access |
Last edited by: PISCEAN 2010 at: 06/16/2020 13:52:00Last edited by: Jen_Moderator at: 06/17/2020 07:04:46Optimized links. |
|
This contribution was helpful to1 thankful Users |