7/12/2019 2:28 PM | |
Posts: 112 Rating: (11) |
HI Anklesh plz share your experience how to solve the problem Rana Ali |
7/16/2019 8:54 AM | |
Joined: 10/27/2009 Last visit: 3/15/2024 Posts: 455 Rating: (77) |
"..."START" Must on for atleast one scan of PLC do not keep it continuously ON..." That described behavour leads to a misfunction in the NC! The "Start" signal have to keep on TRUE until a response signal appears ("InPos" or "Error") In some cases (e.g. Spindle control) on PLC cycle might be suffcient, because the response signal appears very quickly. (he FC18 outputs basically just a Mx Sxxxx) Especially for an axis movement that procedure does not help! Refer to the attached documentation, page 1079. AttachmentFunction Manual Basic Functions FC18 .pdf (244 Downloads) |
hope that helps |
|