1/18/2018 6:17 PM | |
Posts: 3 Rating: (0) |
Hi, im new on this forum and i have the same problem. But i buy a new control sinumerik 808D with V60 Drivers and the drivers show "S-4" all the time. How can i modify this params? DB3800.DBX2.1 -->Drive enable( First axis for ex: X axis) DB3800.DBX4001.7 -->Pulse enable DB3800.DBX1.5-->Measuring system1 I think that. I dont find the way to see or modify the parameters, its a "secret" menu? Best Regards ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 1/19/2018 10:04:12 AMNew subject after splitting |
|
1/19/2018 3:26 AM | |
Posts: 112 Rating: (11) |
Hi no it is not secret menu select menu selecct then services then diagnosis then PLC write related no you can see Bit status Rana Ali |
1/19/2018 12:34 PM | |
Posts: 3 Rating: (0) |
this is my machine data... |
1/19/2018 12:46 PM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877)
|
Hello, if you have PG/PC with Programing Tool PLC808, you can establish the connection & go on line & check the logic to find out why drive enable & pulse enable signals are missing. It will be more user friendly. If you don't have, still you can check the PLC on line on 808 PPU. To acess PLC on line press SHIFT + SYSTEM/ALARM key to enter in SYSTEM operating area, press PLC > PLC program softkeys to open PLC program stored in memory. Here wyou can acess different windows & you can on line monitor PLC. Please download manual from below link & refer chapter 2.5 PLC diagnosis page 29 for more details. SINUMERIK 808D DiagnosticsBelow guide will help you to commission controller. SINUMERIK 808D Commissioning GuideHTH. |
Last edited by: Jen_Moderator at: 1/19/2018 1:21:48 PMInserted right links. |
|