9/25/2017 12:22 PM | |
Posts: 9 Rating: (0) |
Dear All, On my vertical borer machine with 840d control I am getting alarms no. 710531, 710540, 710623. Suggest me which DB address I need to check for these alarm nos. ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 9/26/2017 7:07:35 AMNew subject after splitting |
|
10/4/2017 10:29 AM | |
Joined: 4/23/2010 Last visit: 12/31/2023 Posts: 8092 Rating: (877) |
710531 = DB2.DBX223.7 710540 = DB2.DBX225.0 710623 = DB2.DBX230.7 |
1/15/2019 9:19 PM | |
Posts: 1 Rating: (0) |
Merhaba tum alarmlar ve DB nin karsiliklari varmi verebilirmisin |