4/4/2012 3:02 PM | |
Joined: 7/18/2011 Last visit: 10/9/2023 Posts: 521 Rating: (91) |
Hi Nisse11, The code you are trying to convert is part of the COM PMC package, and is used for visualisation system with CP cards like CP 526/527/528. You cannot convert these blocks into S7, since you cannot use these CP cards in S7. COM PMC consists of several blocks (FB141-FB144, FB151-FB155, PB3, PB6 ,PB7) Of course those blocks can be renamed in your application To learn more about build in communications blocks like FB 244 (SEND) and it's parameters check out chapter 11 of this manual Kind regards, BV |
4/5/2012 10:03 AM | |
Posts: 30 Rating: (1) |
Thanks a lot. Your help spare me at least 3 or 4 days of work . |
This contribution was helpful to1 thankful Users |