4/23/2018 6:31 PM | |
Joined: 4/15/2018 Last visit: 8/22/2024 Posts: 47 Rating: (0) |
Hi. Can i use variable to set positions range in output cam for hmi ? ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 4/24/2018 11:26:13 AMNew subject after splitting |
|
4/26/2018 9:30 PM | |
Joined: 4/15/2018 Last visit: 8/22/2024 Posts: 47 Rating: (0) |
Hi . Can i read position of virual axe simotion by plc s7 ? Thanks alot |
4/30/2018 10:55 AM | |
Joined: 10/11/2006 Last visit: 9/18/2024 Posts: 5906 Rating: (804)
|
Hello, 4.2.10 Configuration data https://support.industry.siemens.com/cs/ww/en/view/51786364 lreal_var := drive_var.setconfigdata.TypeOfAxis.MaxJerk.maximum; // Read access to saved value lreal_var := drive_var.activeconfigdata.TypeOfAxis.MaxJerk.maximum; // Read access to value currently in effect |
With best regards, |
|
Follow us on