4/20/2009 11:22 AM | |
Joined: 4/24/2006 Last visit: 9/19/2024 Posts: 8739 Rating: (1168) |
Dear vominhtan68, Here is a manual about technology functions of S7-300 compact: http://support.automation.siemens.com/WW/view/en/26090032 http://support.automation.siemens.com/WW/view/en/12429336 At the right, you see 'Info', here you can download some examples. Some extra usefull links: http://support.automation.siemens.com/WW/view/en/13337010 http://support.automation.siemens.com/WW/view/en/18475558 http://support.automation.siemens.com/WW/view/en/18467424 Best regards, Wizard |
Last edited by: Wizard at: 4/20/2009 11:26 AMextra links. |
|
4/25/2009 7:59 AM | |
Posts: 15 Rating: (0) |
Attachmentcpu_send.zip (320 Downloads) |
4/28/2009 7:24 AM | |
Posts: 15 Rating: (0) |
DEAR WIZARD!!! Attachmentcpu_send.zip (289 Downloads) |
4/29/2009 7:31 AM | |
Posts: 15 Rating: (0) |
Dear Wizard !!! |
5/5/2009 7:26 AM | |
Posts: 15 Rating: (0) |
Dear Wizard !!! AfterI have done following your manual.I have seenoutput signal in DB48.DBD18 and DB48.DBD14with high speed at 50HZ of Inverter. When at low speed I can't see any signal at DB48.DBD14 (MEAS-VAL). you could see hardware configuration that i have attachment file couldi please ask you some question? with the parameter in hardware is possible or not ?Have i adjust parameter in hardware configuration ? intergration time :100ms low speed : 0MHZ high speed : 30000000 MHZ max couting, frequency : 30KHZ could you show me to solve this problem? Attachmentcpu_313c.zip (262 Downloads) |
5/5/2009 7:31 AM | |
Posts: 15 Rating: (0) |
Attachmentcpu_313c.zip (277 Downloads) |