7/9/2012 8:51 AM | |
Posts: 10 Rating: (0) |
SIMOTION C240 v4.2, Scout 4.2 , WinCCFlex 2008 SP2 This parameter is not listed in the Flex.Where to find it?
|
7/9/2012 11:57 AM | |
Joined: 4/24/2006 Last visit: 9/23/2024 Posts: 8742 Rating: (1168) |
Hello Ivan_L, Perhaps it is a Compatibility problem. See the following link: With what are SIMATIC WinCC flexible 2008, 2007, 2005 and 2004 compatible? Best regards, Wizard |
7/14/2012 10:45 AM | |
Posts: 251 Rating: (11) |
SIMOTION C240 v4.2, Scout 4.2 , WinCCFlex 2008 SP2 i think they are compatible version how can i find mechanical parameter in flexible_?
|
7/16/2012 5:38 AM | |
Posts: 10 Rating: (0) |
jacek d, you were right. Thanks! |
7/16/2012 11:27 AM | |
Posts: 10 Rating: (0) |
_to.name_of_axis.setconfig.TypeOfAxis.NumberOfDataSets.DataSet_1.ControllerStruct.PV_Controller.kv := HMI_variable; In HMI_variable write from WinCCflex.
|