9/1/2015 10:05 AM | |
Posts: 15 Rating: (0) |
Hi, What does operating status ( - -,I,II ) means in DC drive 6ra70. regards rajesh kumar , india |
9/1/2015 10:30 AM | |
Joined: 3/30/2011 Last visit: 9/22/2024 Posts: 736 Rating: (256) |
Hello, do you have 6RA70 manual?? -- = no torque active I = torque direction 1 forward operation II = torque direction 2 reverse operation Best regards Attachment70k11-e.pdf (269 Downloads) |
★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★ |
|
This contribution was helpful to1 thankful Users |
9/1/2015 2:40 PM | |
Joined: 3/30/2011 Last visit: 9/22/2024 Posts: 736 Rating: (256) |
Inside 6RA70 there is a closed loop speed controller. When speed error is positive drive goes in FWD operation, when error is negative in REV operation. Best Regards |
★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★ |
|
9/2/2015 3:59 AM | |
Posts: 15 Rating: (0) |
Thanks, According to you drive will work in reverse operation & motor will work in forward direction. rajesh,india |