9/18/2010 12:55 PM | |
Posts: 241 Rating: (7) |
Hi, It seems to me that these S5 code converted correctly, you only need to check your Called Block in S7, like FC65.. |
9/27/2010 11:09 AM | |
Joined: 4/5/2006 Last visit: 8/13/2023 Posts: 642 Rating: (131) |
Hello, you must change the order in the source. I have a tool to make this automatically. Regards
André Räppel --------------------------------------------------------------------------------- www.raeppel.de work faster withinnovative PLC-Tools |
9/27/2010 4:11 PM | |
Posts: 14 Rating: (0) |
Thanks for your reply. Can you share the tool to solve my problem ? Thanks in advance!!!!!!!
|
9/28/2010 3:23 PM | |
Joined: 4/5/2006 Last visit: 8/13/2023 Posts: 642 Rating: (131) |
hello, please send me your program and i do this for you. My mailadress you can find on the homepage. Regards
André Räppel --------------------------------------------------------------------------------- www.raeppel.de work faster withinnovative PLC-Tools |
9/30/2010 8:49 AM | |
Posts: 14 Rating: (0) |
Hi; As per our discussion ,i am sending you my original S5 file, converted S7 STL file. when compile the above S7 Program, Error Generate like this: Transpositions in the order of parameters at MAN, LCAL , LCAH ,AUTO, STAT, COMP, _DB, INP1 TO INP7 , NORM, TIMER, SIGN, NYIS, NYOP, RC, FAST etc. can result in transpositions/shifts in comments even in subsequent statements. Regards Chittaranjan sahu Attachments5_7.zip (39 Downloads) |
9/30/2010 12:53 PM | |
Joined: 8/27/2006 Last visit: 4/23/2024 Posts: 719 Rating: (88) |
If it's OK, can you tell the name of the tool? |
The more you know, The more you know that you don't know |
|
9/30/2010 3:42 PM | |
Joined: 4/5/2006 Last visit: 8/13/2023 Posts: 642 Rating: (131) |
Yes, i can do this ;-) The name is ChangeParameter http://raeppel.de/tools/changeparameter.htm Regards
André Räppel --------------------------------------------------------------------------------- www.raeppel.de work faster withinnovative PLC-Tools |
9/30/2010 10:05 PM | |
Joined: 4/5/2006 Last visit: 8/13/2023 Posts: 642 Rating: (131) |
Hello, here is the source. 2 Calls have an error - they have not enough parameters. Maybethe blocks are not used?
Regards André Räppel --------------------------------------------------------------------------------- www.raeppel.de work faster withinnovative PLC-Tools Attachment251004AC.zip (41 Downloads) |
10/5/2010 11:00 PM | |
Posts: 14 Rating: (0) |
Hi; Thanks a lot. I had modified the program and S7 STL source file is like this. How can i remove the error generated like Transposition of parameter and missing parameters in FC call in parameter _DB. I am attaching the file. Can anyone help me to remove errors. This is like nightmare!!!!!!!! Chittaranjan sahu
Attachments7 stl.zip (59 Downloads) |
10/6/2010 8:31 AM | |
Joined: 4/5/2006 Last visit: 8/13/2023 Posts: 642 Rating: (131) |
Hello, missing parameters -> i have removed FC257/FC258 from the source file, they are not used You must copy the following blocks from Standard Library\S5-S7 Converting BlocksFC68 FC101 as FC1050
André Räppel --------------------------------------------------------------------------------- www.raeppel.de
work faster withinnovative PLC-Tools Attachmentnew.zip (45 Downloads) |
10/7/2010 9:32 AM | |
Posts: 14 Rating: (0) |
Thanks for ur reply. But i do not want to delete FC257 and FC258 as it require in the program. I am introducing FC277[ PB213 in s5] in modification. can any-one help mehelp me to shorted out errors. Thanks in advance!!!!!!
Attachment251004AC_original.AWL.zip (48 Downloads) |