6/6/2021 9:57 PM | |
Joined: 3/30/2020 Last visit: 4/24/2024 Posts: 4435 Rating: (925) |
This sounds like a driver issue. This article looks helpful in understanding what could be the problem: https://tencomputer.com/fix-kmode-exception-not-handled-windows-10/ |
Activities of this user is voluntary. There is no obligation or liability placed on this user. Though optional, your 'please' and 'thank you' is highly valued. |
|
6/7/2021 10:00 AM | |
Posts: 1 Rating: (0) |
Samme issue here with V16. Perfect timing since I have my last exam today in TIA portal.... |
6/11/2021 1:02 PM | |
Joined: 6/5/2015 Last visit: 1/26/2024 Posts: 1 Rating: (1) |
Cause is a crash of the NDIS 6.30 LightWeight Filter Driver. PS: Also downgrading to 20H1 will not work. MINIDUMP DEBUG
CompanyName: Microsoft Corporation ProductName: Microsoft® Windows® Operating System InternalName: WFPLWFS.SYS OriginalFilename: WFPLWFS.SYS ProductVersion: 10.0.19041.867 FileVersion: 10.0.19041.867 (WinBuild.160101.0800) FileDescription: WFP NDIS 6.30 Lightweight Filter Driver LegalCopyright: © Microsoft Corporation. All rights reserved. WORKAROUND As a workaround to connect via OpenVPN or other clients (SSLPVN Watchguard, Sonicwall etc...) You can use Autoruns by sysinternals (Autoruns Sysinternals Download) Use the Filter 'simatic' and disable all entries. PnDiscovery will be disabled, but you can try to enable it again via Autoruns but results may vary. |
This contribution was helpful to3 thankful Users |
10/4/2021 2:05 PM | |
Joined: 10/28/2009 Last visit: 4/4/2024 Posts: 10 Rating: (2) |
It solved my problem too. Thanks! I'm thinking what will I do, when I have to program PLC over OpenVPN? |
11/17/2021 10:54 AM | |
Joined: 5/15/2019 Last visit: 3/30/2022 Posts: 9 Rating: (0) |
+1, same same. openVPN, TAP driver. üdv! Regards! |
11/18/2021 2:03 PM | |
Posts: 23 Rating: (1) |
i am having this exact issue as well. When i try to use sinema RC to VPN into a PLC i get this error. |
11/24/2021 3:25 PM | |
Posts: 23 Rating: (1) |
For those still encountering this issue. I reached out to Siemens support and this was there recommendation to resolve the issue. I recently installed TIA17 and it basically created this issue when ever i tried to connect to anything using Sinema RC. "The issue is caused by a communication driver in Step 7 V17. There are a couple ways to correct the issue. The preferred way is installed Step 7 V17 update 1 from the link below: |
This contribution was helpful to3 thankful Users |
11/25/2021 2:08 PM | |
Joined: 6/4/2019 Last visit: 2/21/2024 Posts: 5 Rating: (4) |
Thanks a lot. It works for me. |
12/2/2021 8:08 AM | |
Joined: 8/3/2017 Last visit: 2/7/2024 Posts: 1085 Rating: (53) |
HI AutoGen, please read the replies in this topic carefully, e.g. this post:
Hope it helps^^ BR |
Please, check out the forum search to find already existing topics regarding your issue and to get some hints. |
|
12/13/2021 2:10 PM | |
Joined: 1/19/2016 Last visit: 4/16/2024 Posts: 25 Rating: (2) |
After update everything is ok |
This contribution was helpful to1 thankful Users |
1/23/2022 8:23 PM | |
Joined: 1/26/2007 Last visit: 4/2/2024 Posts: 123 Rating: (4) |
Hello, Friday i have installed TIA V 17 along TIA V14 that i was using for long time, but yesterday i was seeing i am not able to use OPEN VPN anymore. For me , i was able to establish connection to target, but i was not able to open online connection=> BSOD. For me was strange cause after i was establish connection and ping target=> BSOD. First i have made the first solution and unclick SIMATIC Industrial Ethernet(ISO), but after this i was not able to ping target/ or connect. After install both of update from link everithing is ok. Thank you for help! |
This contribution was helpful to1 thankful Users |
4/7/2022 9:10 AM | |
Joined: 5/4/2020 Last visit: 1/10/2024 Posts: 1 Rating: (0) |
Yes it works. I was very frustate with it, if is necessary to work from home. Many thanks to U. |
6/9/2022 2:14 PM | |
Joined: 6/9/2017 Last visit: 5/31/2023 Posts: 6 Rating: (0) |
This fixed my problem with FortiClient VPN 7.0.5.0238 and TIA Software V15.1. Thanks! |
1/4/2024 4:57 PM | |
Joined: 12/30/2019 Last visit: 4/16/2024 Posts: 25 Rating: (2) |
As others have said, Installing the latest update fixed the issue for me. I used Update 7 which you can find here Updates for STEP 7 V17, S7-PLCSIM V17 and WinCC V17 - ID: 109784441 - Industry Support Siemens
|
Last edited by: Jen_Moderator at: 01/08/2024 08:34:21Link optimized. |
|