Posts: 138 Rating: (0) |
Yeh Gunners u can use 315-2DP with software redundancy package. Just go through this manual and u will do it. Manual Download Regards, HIKE |
7/7/2010 8:16 PM | |
Joined: 7/2/2008 Last visit: 8/26/2024 Posts: 928 Rating: (308)
|
Hello Gunners, The S7-315F-2DP can be used for software redundancy no doubt since it has been mentioned here. However, this doesn't mean you can use software redundancy in fail safe applications. In software redundancy it's just a normal CPU. Sometimes it's feasible to use 315F-2DP as a normal CPU because it has bigger memory than 315-2DP witha smallprice difference. So, it's better than going to 317-2DP with big price difference.
I'm sorry but you don't have a chance with S7-300. The onlyTUV certified redundant CPUs in Siemens are the 400H ones. Try your luck with S7 412-3Hbut be careful since it's limited to 100 F I/Os. Best regards. H-H |