6/30/2009 2:40 AM | |
Joined: 12/20/2008 Last visit: 8/12/2024 Posts: 556 Rating: (236) |
As far I have heard you cant program in STL in S71200. For details clickhere |
6/30/2009 7:52 AM | |
Joined: 10/7/2005 Last visit: 9/23/2024 Posts: 3022 Rating: (1054) |
Which is exactly why it is on ROSA's wishlist. My S7-1200 wishlist looks like this (in order of priority): 1.) STL programming support 2.) STL programming support 3.) STL programming support 4.) STL programming support . . . . |
Last edited by: fritz at: 6/30/2009 7:53 AMCheers |
|
6/30/2009 2:24 PM | |
Posts: 49 Rating: (18) |
May be, on-board DP port with SIMATIC PDM compatibility... Iwish so..... |
6/30/2009 2:36 PM | |
Joined: 3/21/2006 Last visit: 9/10/2024 Posts: 10228 Rating: (1181) |
Hello guys, So very interesting discussion. But I think IBN-Service is right about S7-300. With your wishes we can reach S7-300 CPU possibilities. But what about price? I don't think that the price will keep the same levels. More possibilities means higher price. And finaly we will have the new version of S7-300. I think that for the moment they will keep S7-1200 like hardware at this position and probably only will fix (add) some features in software. Like this ones that Pegaia and Fritz already suggested. If we follow the logic S7-1200 should be "weaker" then S7-1300. . Best regards Hristo Mihalev |
Last edited by: UMENCHO at: 6/30/2009 2:37 PM |
|
This contribution was helpful to1 thankful Users |
7/1/2009 5:08 PM | |
Joined: 9/23/2005 Last visit: 9/19/2024 Posts: 4347 Rating: (1446)
|
Hi, I agree with Arunakat1, we must stay on the theme: whish list. Despite of all, any customer feed backSHOULD be listen. What could be done in the praxis, it is other theme, for other Tread. About blue tooth, an alternative is Wireless Ethernet communication, like ET200Pro has. |
Denilson Pegaia |
|
This contribution was helpful to1 thankful Users |
7/21/2009 10:41 AM | |
Joined: 9/1/2005 Last visit: 9/18/2024 Posts: 4104 Rating: (195) |
Dear forum members, we splitted some of your posts to different threads, because we think that some posts belong to other topics. We created three new threads where you can find all the posts which wre here. wish list-Step7 Basic V10.5. Price discussion. wish list - coomunication. Best regards CS Moderator |
My Forum is the place to personalize your profile, |
|
8/6/2009 12:49 PM | |
Posts: 76 Rating: (1) |
I wish Web-Server (i have never used it at all and i wanna try) |
9/8/2009 8:34 AM | |
Posts: 4 Rating: (0) |
My wishlist would be a webserver where I can program in HTML code a HMI |
11/7/2010 8:33 PM | |
Joined: 3/31/2010 Last visit: 6/14/2024 Posts: 21 Rating: (12) |
Here are the shortcomings I've found in STEP 7 Basic V10.5 SP2 Update 1. Serious: 1. PLC simulator. 2. SCL programming language. 3. Undo function in editors. 4. CSV export/import of PLC/HMI tags, hardware configuration and Project texts (Languages & Resources). 5. Online program change. 6. Multi-instance FB (static variable of FB type). 7. Web server. 8. Dynamic indexing of arrays - array[variable]. - Found it among hidden instructions: FieldRead and FieldWrite. 9. Dynamic access to memory STL-style: LAR1, DBW, DIW etc. 10. Blockmove source and destination cannot be of different data types (it may be called a feature, but without dynamic access to memory it can be the last hope to do some efficient conversion). 11. Arrays of string and arrays of structures. =============Inconveniences: 1. Rows cannot be dragged in DB and in Interface declaration table; changing the order of rows is quite a pain; also not possible to move rows from one area to another (e.g. from Temp to Static) neither by dragging, nor by cut/paste. 2. Copied rows cannot be pasted in DB and in Interface declaration table over a blank row, only over another existing row or the area title (e.g. Temp, Static) - not intuitive. 3. When blocks (DB, FB, FC, OB) are copied their numbers are not changed automatically, hence a compilation error (https://www.automation.siemens.com/tf/WW/en/Posts/47970#top). 4. Not possible to jump through networks with Up and Down arrow keys when the cursor is over the network number (although compensated by Close all networks). 5. No hot keys for "Go to next/previous usage". Also this function is not there for the variables in Interface declaration table. 6. "Replace all" button is constantly disabled. 7. Not possible to copy all HMI tags into WinCC Flexible runtime simulator: neither by copy/paste, nor export/import (only AutoHotkey keyboard macro helps). |
Last edited by: DrewBuld at: 11/11/2010 2:51 PMLast edited by: DrewBuld at: 11/9/2010 8:59 PMLast edited by: DrewBuld at: 11/7/2010 9:23 PM |
|
11/9/2010 7:41 PM | |
Joined: 5/4/2009 Last visit: 5/28/2024 Posts: 914 Rating: (40) |
Also What about Webserver? Regards. Tomy.
|
Aim Higher |
|
4/25/2011 12:55 PM | |
Joined: 9/23/2005 Last visit: 9/19/2024 Posts: 4347 Rating: (1446)
|
Hi,
Delivery release SIMATIC STEP 7 Professional V11
|
Denilson Pegaia |
|
4/26/2011 11:02 AM | |
Posts: 6 Rating: (0) |
Without being able toread the whole thread... My wish list too: 1) Keep price low for S7-1200. 2) Add simulation to the TIA or develop an extra program. |
4/26/2011 1:02 PM | |
Posts: 211 Rating: (6) |
I wish that KTP upload is possible too (now just download, no upload). |
10/12/2012 8:08 AM | |
Posts: 4 Rating: (0) |
CAM POSITIONER FUNCTION |
10/13/2012 1:18 PM | |
Posts: 8946 Rating: (999) |
Filtersettings for the Input of HSC. |
4/30/2013 2:54 PM | |
Joined: 8/1/2012 Last visit: 9/2/2024 Posts: 179 Rating: (15) |
If there were a separate section for Tips in froums it would be better and more available for members |
|
|
Follow us on