(0)| 4/3/2018 6:16 PM | |
|
Joined: 2/16/2018 Last visit: 7/24/2025 Posts: 24 Rating:
|
Sorry to gravedig, but is this possible in VBS? Thanks ------------------------------------------------------------------------------------------ |
Last edited by: Jen_Moderator at: 4/4/2018 12:57:13 PMNew subject after splitting |
|
| 4/5/2018 1:44 PM | |
|
Joined: 10/3/2010 Last visit: 1/14/2026 Posts: 1572 Rating:
|
Depending on your needs, you can create something similar with VBS. First create an internal tag of the type "Text tag 8-bit". You can manipulate the value of this internal tag by VBS to write another tagname in it. In your I/O-field, you can link the outputvalue-property to the internal tag and enable the "indirect" checkbox behind it. This way you can change the tag used in an I/O-field just by write another tagname to the internal text tag. |
|
B r g d s , |
|
| 1/13/2022 3:49 PM | |
|
Joined: 10/3/2010 Last visit: 1/14/2026 Posts: 1572 Rating:
|
hi vcamp7 did you check if my previous reply could work for your needs? |
|
B r g d s , |
|
Follow us on