3/12/2017 10:47 AM | |
Posts: 6 Rating: (5) |
Hello All! I have sucessfull installation of Step7 5.5 (2010 SR4) on Windows 10 latest update. 1. Install TIA portal V14 (To have step7 drivers and ALM latest version) 2. Extract from attachments 2 files 3. Replace them in Step7 2010 SR4 installation:
4. Install Step7 v5.5 with all components You need 5. Install WinCC 7.4 with Update 2 (optional) to have complete system (AS-OS Engineering in WinCC works as it should work). Thats all! Everything works much faster than Windows 7 or Windows 8.1. Attached fixed files (Read next posts for archive z01 and z02 parts)
AttachmentFixedFiles.zip (2206 Downloads) |
Last edited by: Ritvars Rižikovs at: 3/12/2017 10:57:01 AM |
|
This contribution was helpful to3 thankful Users |
3/12/2017 10:51 AM | |
Posts: 6 Rating: (5) |
z01
AttachmentFixedFiles z01.zip (2038 Downloads) |
This contribution was helpful to1 thankful Users |
3/12/2017 10:52 AM | |
Posts: 6 Rating: (5) |
z02
AttachmentFixedFiles z02.zip (1820 Downloads) |
This contribution was helpful to2 thankful Users |
3/23/2017 7:32 AM | |
Posts: 1 Rating: (0) |
Dear Sir, This is trial version. please inform complete version |
4/6/2017 8:45 AM | |
Joined: 12/2/2015 Last visit: 6/30/2024 Posts: 64 Rating: (7) |
second method does not work because Windows Enabler does not active any buttons in Win 10.
|
4/6/2017 10:52 AM | |
Joined: 12/2/2015 Last visit: 6/30/2024 Posts: 64 Rating: (7) |
Works brilliant! |
4/8/2017 6:00 AM | |
Posts: 1 Rating: (0) |
hello Pablo how and which area we needs to modify the setup.exe |
4/27/2017 8:02 PM | |
Posts: 1 Rating: (0) |
good evening I would like to help a young person for the purpose of installing s7-300 sp1 on Windows 10 |
4/30/2017 6:36 PM | |
Joined: 1/10/2015 Last visit: 9/15/2024 Posts: 44 Rating: (0) |
Will the version of S7 5.6 only available inJuly or I understood incorrectly? |
5/4/2017 2:50 PM | |
Posts: 1 Rating: (0) |
PLEASE update your info to say that one needs to find in Notepad everything that says en-US and replace with your local language, like da-DK, in the install.bat file. Otherwise it won't work. Also you need to get this file and replace it with the one in the folder with the install.bat file. Please use the x64 helpfile from XP (only one that works). Remember to run the install.bat file as ADMIN! That's how it worked for me! Thanks everyone! Was a long trip but finally everything works and I can finally simulate two plc's to communicate with each other and go online on PLC's remotely via a AnyConnect VPN! Awesome! Attachmentwinhlp32 XP x64.zip (1107 Downloads) |
Last edited by: TwentyEighteen at: 5/4/2017 2:52:36 PMLast edited by: TwentyEighteen at: 5/4/2017 2:53:13 PMLast edited by: TwentyEighteen at: 5/4/2017 2:53:48 PM |
|
This contribution was helpful to1 thankful Users |